background image

-2-

This manual describes the installation and operation of the Ashley, AP130 pellet stove.

•  IMPORTANT: Read this entire manual before 

installing and operating this product. Failure to do 

so may result in property damage, bodily injury, 

or even death. Proper installation of this stove is 

crucial for safe and efficient operation.

• 

Install vent at clearances specified by the vent 

manufacturer.

• 

If a chimney or creosote fire occurs, press the “OFF” 

button immediately. Do not unplug the unit.

•  Do not connect the pellet vent to a vent serving 

any other appliance or stove.

• 

Do not install a flue damper in the exhaust venting 

system of this unit.

•  Use of outside air is not required for this unit.

• 

Contact your local building officials to obtain 

a permit and information on any additional 

installation restrictions or inspection requirements in 

your area.

•  Do not throw this manual away. This manual has 

important operating and maintenance instructions 

that you will need at a later time. Always follow the 

instructions in this manual.

•  This appliance is designed for the use of pelletized 

fuel that meet or exceed the standard set by the 

Pellet Fuel Institute(PFI).

•  Never use gasoline, gasoline-type lantern fuel, 

kerosene, charcoal lighter fluid, or similar liquids to 

start or ’freshen up’ a fire in this stove. Keep all such 

liquids well away from the stove while it is in use.

•  A working smoke detector must be installed in the 

same room as this product.

•  Do not unplug the stove if you suspect a 

malfunction. Turn the ON/OFF SWITCH to ”OFF’ and 

contact your dealer.

•  Your stove requires periodic maintenance and 

cleaning (see ”MAINTENANCE ”). Failure to 

maintain your stove may lead to improper and/or 

unsafe operation.

•  Disconnect the power cord before performing any 

maintenance! NOTE: Turning the ON/OFF Switch 

to ”OFF” does not disconnect all power to the 

electrical components of the stove.

•  Never try to repair or replace any part of the stove 

unless instructions for doing so are given in this 

manual. All other work should be done by a trained 

technician.

•  Do not operate your stove with the viewing door 

open. The auger will not feed pellets under these 

circumstances and a safety concern may arise 

from sparks or fumes entering the room.

•  Allow the stove to cool before performing any 

maintenance or cleaning. Ashes must be disposed 

in a metal container with a tight fitting lid. The 

closed container of ashes should be placed on a 

non-combustible surface or on the ground, well 

away from all combustible materials, pending final 

disposal.

• 

The exhaust system should be checked monthly 

during the burning season for any build-up of soot 

or creosote.

•  Do not touch the hot surfaces of the stove. Educate 

all children on the dangers of a high-temperature 

stove. Young children should be supervised when 

they are in the same room as the stove.

•  The hopper and stove top will be hot during 

operation; therefore, you should always use some 

type of hand protection when refueling your stove.

•  A power surge protector is required. This unit must 

be plugged into a 110 - 120V, 60 Hz grounded 

electrical outlet. Do not use an adapter plug 

or sever the grounding plug. Do not route the 

electrical cord underneath, in front of, or over the 

heater. Do not route the cord in foot traffic areas or 

pinch the cord under furniture.

•  The heater will not operate during a power outage. 

If a power outage does occur, check the heater 

for smoke spillage and open a window if any 

smoke spills into the room.

•  The feed door must be closed and sealed during 

operation.

• 

Never block free airflow through the open vents of 

the unit.

•  Soot and Flyash: Formation and Need for Removal 

– The products of combustion will contain small 

particles of flyash. The flyash will collect in the 

exhaust venting system and restrict the flow of the 

flue gases. Incomplete combustion, such as occurs 

during startup, shutdown, or incorrect operation of 

the room heater will lead to some soot formation 

which will collect in the exhaust venting system. 

The exhaust venting system should be inspected 

at least once every year to determine if cleaning is 

necessary.

•  Keep foreign objects out of the hopper.

•  The moving parts of this stove are propelled by high 

torque electric motors. Keep all body parts away 

from the auger while the stove is plugged into an 

electrical outlet. These moving parts may begin to 

move at any time while the stove is plugged in.

• 

Do not place clothing or other flammable items on 

or near this stove.

•  When installed in a mobile home, the stove must 

be grounded directly to the steel chassis and 

bolted to the floor. WARNING—THIS UNIT MUST 

NOT BE INSTALLED IN THE BEDROOM (per HUD 

requirements). CAUTION—The structural integrity of 

the mobile home floor, wall, and ceiling/roof must 

be maintained.

•  This appliance is not intended for commercial use.

* This appliance is a freestanding heater. It is not intended to be attached to any type of ducting. It is not a 

furnace.

Safety Precautions

Содержание ASHLEY AP130

Страница 1: ...URE REFERENCE United States Stove Company 227 Industrial Park Road South Pittsburg TN 37380 Please read this entire manual before installation and use of this appliance Failure to follow these instruc...

Страница 2: ...The closed container of ashes should be placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked monthl...

Страница 3: ...no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust h...

Страница 4: ...an NFI certified specialist IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 750 272...

Страница 5: ...m CORNER D Adjacent wall to unit 8 00 203mm ALCOVE E Alcove depth 36 00 914mm 5500 M only F Alcove height 60 00 520mm CLEARANCES Your pellet stove has been tested and listed for installation in reside...

Страница 6: ...the stove use a 3 inch to 4 inch adapter for 4 inch pipe Connection at back of stove must be sealed using Hi Temp RTV Use 4 inch vent if the vent height is over 12 feet or if the installation is over...

Страница 7: ...ith a kit that will handle most of this installation which will include a wall thimble that will allow the proper clearance through a combustible wall Once outside the structure a 3 in 76mm clearance...

Страница 8: ...g of the detector when reloading In addition to the previously detailed installation requirements mobile home installations must meet the following requirements The heater must be permanently bolted t...

Страница 9: ...er of this manual Because a forced draft pressure is required for the combustion process inside your stove it is extremely important that the exhaust system be properly installed and maintained And th...

Страница 10: ...at will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fa...

Страница 11: ...the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Sta...

Страница 12: ...4 Auger Output Test The display will show augr The auger motor is turned on full If the Auger Fuse is not blown and the fuse detection circuit is functioning the Heat Range LED will be lit and the ot...

Страница 13: ...urely closed the safety pressure switch will not allow the stove to feed fuel if there is no draft pressure inside the stove 7 Press the ON button on the control pad and set the heat Setting to your d...

Страница 14: ...ON button on the digital control panel your stove will begin to feed fuel and automatically start within 5 minutes TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that mus...

Страница 15: ...this could damage the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the fir...

Страница 16: ...s down Hopper is empty refill the hopper Loss of draft pressure Make sure that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outsid...

Страница 17: ...g the lighting stage Quickly changes twice per second Flashing Heat Range Setting Indicator This indicates that the stove is in normal operation and that an over temperature condition exists causing t...

Страница 18: ...18 GRAY BLACK Wiring Diagram CORRECT WRONG Insure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 19: ...40 Lock Nut 2 16 25480MB Access Panel 1 17 80461 Power Supply Cord 1 18 80462 Receptacle 3 Prong 1 19 891164 Auger Housing Weldment 1 20 891141 Auger 1 21 891189 Top Bushing Plate 1 22 891132 Bushing...

Страница 20: ...20 11 3 2 1 5 6 4 7 9 8 10 12 Parts Diagram 47 46 48 49...

Страница 21: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 22: ...s pi ces d tach es Gardez ce manuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fi...

Страница 23: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 24: ...2 15 83542 4 40 crou 2 16 25480MB Panneau D acc s 1 17 80461 Cordon D alimentation 1 18 80462 R ceptacle 3 Prong 1 19 891164 Auger Logement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1...

Страница 25: ...20 Sch ma des pi ces 11 3 2 1 5 6 4 7 9 8 10 12 47 46 48 49...

Страница 26: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Страница 27: ...Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur Heat Range clignotant...

Страница 28: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Страница 29: ...le et d paisseur correctes doivent tre utilis es NE substituez PAS le verre avec des mat riaux alternatifs Contactez votre revendeur autoris pour obtenir ce verre R installez le nouveau verre en le fi...

Страница 30: ...fi peut effectuer ces travaux Il est aussi recommand qu avant chaque saison de chauffage le syst me complet soit inspect nettoy et si n cessaire r par par un professionnel Pour nettoyer la chemin e d...

Страница 31: ...sur le bouton OFF arr t et ensuite de nouveau sur le bouton ON marche pour commencer une nouvelle s quence de mise en route 2 Si le po le a refroidi il se r initialisera l tat OFF arr t ce moment l vo...

Страница 32: ...de l eau sal e 11 Bois non s ch ou 12 Produits du papier carton contreplaqu ou panneau de particules L interdiction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de pa...

Страница 33: ...fin se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois au...

Страница 34: ...justez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE L...

Страница 35: ...rage forc e est n cessaire au processus de combustion l int rieur de votre po le il est extr mement important que le syst me d vacuation soit install correctement et maintenu Et que lors du fonctionne...

Страница 36: ...ionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le...

Страница 37: ...s parois et du plafond toit de la maison mobile doit tre maintenue Un d tecteur de fum e fonctionnel doit tre install dans la m me pi ce que ce produit Il doit tre install au moins 15 pieds 4 57 m de...

Страница 38: ...rd en T de regard devra tre plac sur le tuyau avec une sortie 90 degr s hors de la maison ce point une partie de tuyau de 3 pieds 0 91m minimum devra tre ajout e avec un couvercle horizontal qui devra...

Страница 39: ...e doit tre scell en utilisant un produit vulcanis RTV pour temp ratures lev es Utilisez une ventilation de 4 pouces si la hauteur de ventilation est sup rieure 12 pieds ou si l installation se trouve...

Страница 40: ...re minimum plus grand afin d obtenir un acc s commode au panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION...

Страница 41: ...cialiste certifi NFI NE CONNECTEZ PAS CETTE UNIT UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR INSTALLATION INCORRECTE Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnem...

Страница 42: ...ar pied cube diam tre de 1 4 5 16 po longueur non sup rieure 1 5 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les granul s...

Страница 43: ...d entretien ou de nettoyage Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur un...

Страница 44: ...d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agency Certifi aux normes d missions de 2015 particules United...

Отзывы: