DAILY OPERATION

•  The hopper and stove top will be hot during operation; therefore, you should always use some type of hand 

protection when refueling your stove.

•  Never place your hand near the auger while the stove is in operation.

This unit should be filled when the hopper level drops below 3-inches.

In the event of a power outage, the stove will not function. It is very important that unit be vented properly (with 

outside air), as the natural draft is needed to clear the smoke from the stove during a power outage. If the unit 

was “ON” when the power outage occurred, one of the following will take place:

1. 

If the stove is still warm, it will resume feeding fuel and continue to operate normally. If the fire has gone out, 

you will have to press the “OFF” button and then the “ON” button again to begin a new start-up sequence.

2. 

If the stove has cooled-off, it will reset to its “OFF” condition. At this point, you may press the “ON” button and 

the unit will begin a new start-up sequence.

NOTE: The unit will also shut down in the event of an exhaust blower failure; if this is the case, the unit will not re-

start and you must contact customer service.

SAFETY AND CONVENIENCE FEATURES

Your pellet stove incorporates a safety pressure switch that helps ensure that everything is in proper working 

order before feeding fuel to the burn pot. Because the stove works using an induced draft pressure, the stove 

will not continue to operate if the viewing door is left open; or if the exhaust blower fails or the exhaust system is 

blocked.

The temperature limit control (Thermistor) will prevent your stove from operating at abnormally high temperatures. 

Should the stove temperature begin to approach the factory pre-set limit, the temperature limit control will 

automatically slow down the auger feed rate until the temperature returns to a normal condition. Even though 

the heater will operate on the highest setting, we recommend to operate your heater on this setting for only a 

short period of time. (1 hour etc.)

Your pellet stove also includes an auto-start igniter as a standard feature. The use of other fire starter materials 

(wood chips, starter gel, etc.) is not necessary. By simply pressing the “ON” button on the digital control panel, 

your stove will begin to feed fuel and automatically start within 5 minutes.

TAMPER WARNING

This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal 

regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating 

instructions in this manual.

•  Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards.

• 

Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any 

inspection, cleaning, or maintenance work.

•  Never perform any inspections, cleaning, or maintenance on a hot stove.

• 

Do not operate stove with broken glass , leakage of flue gas may result.

• 

WARNING: The chimney and chimney connector must be kept in good condition and clean.

EXHAUST SYSTEM

Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine 

with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a 

newly started fire or from a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When 

ignited, this creosote makes an extremely hot fire, which may damage the chimney or even destroy the house. 

Despite their high efficiency, pellet stoves can accumulate creosote under certain conditions.

Fly Ash – This accumulates in the horizontal portion of an exhaust run. Though non-combustible, it may impede 

the normal exhaust flow. It should therefore be periodically removed.

Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to 

determine if a creosote or fly ash build-up has occurred. If creosote has accumulated, it should be removed to 

reduce the risk of a chimney fire. Inspect the system at the stove connection and at the chimney top. Cooler 

surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as 

from the bottom. The creosote should be removed with a brush specifically designed for the type of chimney 

in use. A qualified chimney sweep can perform this service. It is also recommended that before each heating 

season the entire system be professionally inspected, cleaned and, if necessary, repaired. To clean the chimney, 

disconnect the vent from the stove.

Maintenance

Содержание ASHLEY AP130

Страница 1: ...URE REFERENCE United States Stove Company 227 Industrial Park Road South Pittsburg TN 37380 Please read this entire manual before installation and use of this appliance Failure to follow these instruc...

Страница 2: ...The closed container of ashes should be placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked monthl...

Страница 3: ...no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust h...

Страница 4: ...an NFI certified specialist IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 750 272...

Страница 5: ...m CORNER D Adjacent wall to unit 8 00 203mm ALCOVE E Alcove depth 36 00 914mm 5500 M only F Alcove height 60 00 520mm CLEARANCES Your pellet stove has been tested and listed for installation in reside...

Страница 6: ...the stove use a 3 inch to 4 inch adapter for 4 inch pipe Connection at back of stove must be sealed using Hi Temp RTV Use 4 inch vent if the vent height is over 12 feet or if the installation is over...

Страница 7: ...ith a kit that will handle most of this installation which will include a wall thimble that will allow the proper clearance through a combustible wall Once outside the structure a 3 in 76mm clearance...

Страница 8: ...g of the detector when reloading In addition to the previously detailed installation requirements mobile home installations must meet the following requirements The heater must be permanently bolted t...

Страница 9: ...er of this manual Because a forced draft pressure is required for the combustion process inside your stove it is extremely important that the exhaust system be properly installed and maintained And th...

Страница 10: ...at will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fa...

Страница 11: ...the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Sta...

Страница 12: ...4 Auger Output Test The display will show augr The auger motor is turned on full If the Auger Fuse is not blown and the fuse detection circuit is functioning the Heat Range LED will be lit and the ot...

Страница 13: ...urely closed the safety pressure switch will not allow the stove to feed fuel if there is no draft pressure inside the stove 7 Press the ON button on the control pad and set the heat Setting to your d...

Страница 14: ...ON button on the digital control panel your stove will begin to feed fuel and automatically start within 5 minutes TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that mus...

Страница 15: ...this could damage the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the fir...

Страница 16: ...s down Hopper is empty refill the hopper Loss of draft pressure Make sure that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outsid...

Страница 17: ...g the lighting stage Quickly changes twice per second Flashing Heat Range Setting Indicator This indicates that the stove is in normal operation and that an over temperature condition exists causing t...

Страница 18: ...18 GRAY BLACK Wiring Diagram CORRECT WRONG Insure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 19: ...40 Lock Nut 2 16 25480MB Access Panel 1 17 80461 Power Supply Cord 1 18 80462 Receptacle 3 Prong 1 19 891164 Auger Housing Weldment 1 20 891141 Auger 1 21 891189 Top Bushing Plate 1 22 891132 Bushing...

Страница 20: ...20 11 3 2 1 5 6 4 7 9 8 10 12 Parts Diagram 47 46 48 49...

Страница 21: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 22: ...s pi ces d tach es Gardez ce manuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fi...

Страница 23: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 24: ...2 15 83542 4 40 crou 2 16 25480MB Panneau D acc s 1 17 80461 Cordon D alimentation 1 18 80462 R ceptacle 3 Prong 1 19 891164 Auger Logement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1...

Страница 25: ...20 Sch ma des pi ces 11 3 2 1 5 6 4 7 9 8 10 12 47 46 48 49...

Страница 26: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Страница 27: ...Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur Heat Range clignotant...

Страница 28: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Страница 29: ...le et d paisseur correctes doivent tre utilis es NE substituez PAS le verre avec des mat riaux alternatifs Contactez votre revendeur autoris pour obtenir ce verre R installez le nouveau verre en le fi...

Страница 30: ...fi peut effectuer ces travaux Il est aussi recommand qu avant chaque saison de chauffage le syst me complet soit inspect nettoy et si n cessaire r par par un professionnel Pour nettoyer la chemin e d...

Страница 31: ...sur le bouton OFF arr t et ensuite de nouveau sur le bouton ON marche pour commencer une nouvelle s quence de mise en route 2 Si le po le a refroidi il se r initialisera l tat OFF arr t ce moment l vo...

Страница 32: ...de l eau sal e 11 Bois non s ch ou 12 Produits du papier carton contreplaqu ou panneau de particules L interdiction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de pa...

Страница 33: ...fin se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois au...

Страница 34: ...justez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE L...

Страница 35: ...rage forc e est n cessaire au processus de combustion l int rieur de votre po le il est extr mement important que le syst me d vacuation soit install correctement et maintenu Et que lors du fonctionne...

Страница 36: ...ionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le...

Страница 37: ...s parois et du plafond toit de la maison mobile doit tre maintenue Un d tecteur de fum e fonctionnel doit tre install dans la m me pi ce que ce produit Il doit tre install au moins 15 pieds 4 57 m de...

Страница 38: ...rd en T de regard devra tre plac sur le tuyau avec une sortie 90 degr s hors de la maison ce point une partie de tuyau de 3 pieds 0 91m minimum devra tre ajout e avec un couvercle horizontal qui devra...

Страница 39: ...e doit tre scell en utilisant un produit vulcanis RTV pour temp ratures lev es Utilisez une ventilation de 4 pouces si la hauteur de ventilation est sup rieure 12 pieds ou si l installation se trouve...

Страница 40: ...re minimum plus grand afin d obtenir un acc s commode au panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION...

Страница 41: ...cialiste certifi NFI NE CONNECTEZ PAS CETTE UNIT UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR INSTALLATION INCORRECTE Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnem...

Страница 42: ...ar pied cube diam tre de 1 4 5 16 po longueur non sup rieure 1 5 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les granul s...

Страница 43: ...d entretien ou de nettoyage Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur un...

Страница 44: ...d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agency Certifi aux normes d missions de 2015 particules United...

Отзывы: