background image

INSTRUCTION MANUAL

FOR INSTALLATION

USE AND MAINTENANCE

TYPE

RNO 200

MODEL

Содержание RNO 200

Страница 1: ...INSTRUCTION MANUAL FOR INSTALLATION USE AND MAINTENANCE TYPE RNO 200 MODEL...

Страница 2: ...Y FLUE p 8 The Chimneypot INSTALLATION p 10 Initial advices OPERATION p 12 Lighting and combustion COMBUSTIBLE p 15 SAFETY p 16 External air inlet Home fire safety Installation distances from flammabl...

Страница 3: ...Collarin uscita fu Smoke e collar Canale da fumo Flue pipe Uscita aria calda di convezione Convetion hot air exit Scambiatore di calore in acciaio a fascio tubiero Tube bundle steel recycler Immissio...

Страница 4: ...insulation is also recommended when the chimney is installed inside a masonry This will prevent the cold air from creeping between the steel pipe and the wall Furthermore a good insulation will be nee...

Страница 5: ...mmended to install an appropriate chimneypot It must be insulated like the chimney flue until its holes In case the brick chimney flue has an internal pipe this pipe shall continue until the holes in...

Страница 6: ...an incinerator or in any other way different from the one it has been conceived for Do not use fuels different from those recommended Do not use liquid fuels The stove especially the external surfaces...

Страница 7: ...s also necessary to clean the fireplace area immediately behind the door from the ashes in order to keep the primary air inlet open The ash found in this area can be pushed towards the back of the fir...

Страница 8: ...contact the Manufacturer However if the smoke comes out from the stove while loading it ventilate momentarily the room and continue to load more slowly giving time to ignite the wood The fireplace mu...

Страница 9: ...nect the stove to a chimney flue already used for another device Keep away from the fireplace radiation area all combustible and flammable materials wood furniture curtains flammable liquids etc If ne...

Страница 10: ...eplace door In relation to the instructions above it remains at the Customer discretion the decision to install a protective shield around the stove or in front of the fireplace door ASSEMBLY SCHEMES...

Страница 11: ...ase from above Insert primary air dipstick in its hole and screw it Chimley flue hole 1 Position the fireplace in axis with the flue pipe hole 2 Unscrew and remove exchanger Put the 1st ceramic ring o...

Страница 12: ...the internal cleaning of the heat exchanger lift the ceramic top cover unscrew the door on the exchanger it is recommended to moisten the screws with special lubrificants before starting to loo sen a...

Страница 13: ...LA CASTELLAMONTE di R Perino e S Neri Snc Via Casari s n 10081 Castellamonte TO Italy Tel 0039 124 581690 Fax 0039 124 514149 www lacastellamonte it www stackstoves com info lacastellamonte it...

Отзывы: