16
17
SAFETY
External air inlet
Home fire safety
Installation distances from flammable material
Ceramic Lining
The stove must have the necessary air so as to ensure a regular combustion and a healthy environ-
ment, so:
•
Make sure that in the room where the stove is installed there is adequate ventilation, the minimum
recommended section is > 80 cm2 for devices with closed fireplace
•
The air intake must be directly communicating with the room in which the stove is installed. Avoid
any obstruction and protect it with a grid as long as it does not reduce the minimum section.
•
The adjacent room cannot be used as a garage, storage of combustible material or for activities
with risk of fire.
Installation and use of the stove should be in accordance with the instructions of the Manufacturer
and the local rules of habitability.
•
When a flue pipe pass through a wall or ceiling particular methods of installation should be applied
(protection, thermal insulation, distance from heat sensitive materials, etc)
•
Never connect the stove to a chimney flue already used for another device.
•
Keep away from the fireplace radiation area all combustible and flammable materials (wood
furniture, curtains, flammable liquids, etc…)
•
If nearby there are shells in combustible or sensitive to heat materials, an insulating and not
combustible protection must be interponed.
•
If the floor is made in combustible material, at the mouth of the fireplace a protection made
of incombustible material should be placed – with a lateral extension of 20 cm and a frontal
extension of 60 cm.
Minimum installation distances from flammable material:
-minimum distance from lateral flammable wall: 200mm
-minimum distance from flammable rear wall: 200mm
-minimum distance from flammable floor: 80mm
Minimum front distance from flammable material: 1000 mm
•
The various ceramic parts must be handled with extreme care.
•
Check the leveling of the floor where the stove will be installed.
•
If you notice that the packaging is damaged or any lack of professionalism of the transporter at
the stove delivery, sign the note with words “subject to control”.
•
The installation must be done by at least two persons carefully following the installation in-
structions provided in this manual.