21
Electrical Installation
E
M
C
Under the following installation and test conditions the devices comply with the EU
2004/108/EG guideline in standards EN61800-3
Assembly:
The controller is conductively mounted on a 500x500x2 mm blank metal assembly base.
For 10 mm the assembly base is connected with the PE. For 10 mm the motor housing is
connected with the PE. Zero of device
For 2,5mm X-AGND is connected with the assembly base. Device’s –PE - screw X3:6
connected to assembly base with a 4mm line
Control connections:
Signal lines shielded, analog signal lines twisted and shielded
Mains three-phase connection:
3x 400V~ with protective earthed conductor
Motor connection:
Motor connection shielded, surface earth contact
When mounted in machines and installations it is forbidden to start
the proper use of the device until the machine or the installation has
been approved to comply with the regulations of the 2006/42/EG
machine directive and the 2004/108/EG guideline.
For cars ECE-R83, ECE-R100
manufacturer’s certificate is available.
CNC/SPS
X7
1
2
3
PE
X3:
:
PE
PE
R
B
min 4ø
RLG
bl
M
3 bl
:
X9
X8
X1:7
X1:8 X1:9
CAN-
FRG
BUS
RUN
OUT
INC-
L1
L2
L3
GND
X3:
4
5
6
4
5
9
E
A
R
T
H
B
US
E
LE
C
T
RO
NI
C
Maschine frame
Maschine frame
Motor chokes
double grounding
Shield on the
connector housing
Shield on the
connector housing
15 pin connector
ext. regen
resistor
analog
setpoint
Input filter
double grounding
M
oun
tin
g
p
lat
e
A
ll
e
ar
th
con
ne
cti
o
n
to
the
m
ou
nti
ng
pl
at
e
sho
ul
d
be
a
s
sh
or
t
as
pos
si
bl
e
increased demands
only with
min 4ø
min 4ø
Содержание DS-205.4
Страница 3: ...2 DS 205 3 DS403 4 Blank page...
Страница 11: ...Basic Information 10...
Страница 16: ...15 DS 205 3 DS403 4...
Страница 45: ...44 Electrical Installation Optionen...