32
Electrical Installation
C
o
n
tr
o
ls
ig
n
a
ls
Analog inputs
+/- 10V
Characteristics
Differential input
AIN1+/AIN1-
AIN2+/AIN2-
Input resistance
70k
Maximum voltage
+/-12V
Resolution
11Bit + sign
The direction of rotation of the motor can either be changed by swapping
the ± connections at the differential input, or by means of a logic input or by programming.
The analog inputs can be assigned to different functions.
With a digital command value (RS232, x-bus)
- the analog input AIN1can be programmed as external analog speed limit
- and the analog input AIN2 can be programmed as external analog current limit.
Analog /- 10V
Output
Connection
Basic function
Voltage
State
Param.
AOUT1
X2:20
Speed actual value
±
10V
programmable
GND
X2:21
Signal zero
0V
fixed
Sollx
REF150
10k
100k
100k
100nF
15k
10k
100k
15k
IN+
IN-
DSxx/BAxx
1.5V +/- 1.36V
analog
inputs
Input
Plug
Basic- Function
Voltage
Status
Parameter
AIN1+,AIN1-
X1:8, X1:9
Speed setpoint
+/-10V
prog.
AIN2+,AIN2-
X1:15,X1:16
Current limit
+/-10V
prog.
Содержание DS-205.4
Страница 3: ...2 DS 205 3 DS403 4 Blank page...
Страница 11: ...Basic Information 10...
Страница 16: ...15 DS 205 3 DS403 4...
Страница 45: ...44 Electrical Installation Optionen...