27
Setup mode
C o n f i g u r i n g
t h e L a p t i m e r
set this value at 12500.
All five LEDs are used for gear shift indicator,
but they have higher priority than normal LED
warnings. This means, that even if the warning
LEDs might be turned on or are blinking, the
shift lift overrules this and turn all the LEDs
into a shift light indicator when needed.
RPM DELTA
The RPM delta value is the “distance” between
the LEDs when used as a shift light indicator.
If you for example want to shift at 12500 RPM
and set the RPM delta value to 300, the shift
light will turn on at 11900, 12200, 12500,
12800 and 13100 RPM. The smaller delta
value, the faster reacts the shift light.
RPM SHIFT TYPE
The RPM shift lights always blinks in a flashy
way, but with this setting you can select if the
indicator uses the LEDs as single LEDs or all
at once. If set to all at once, all LEDs will flash
when the RPM shift point is reached and the
RPM delta value will not be used.
RPM LIMITER LOG
The RPM filter we use is very advanced and
the purpose it to make the RPM graph look as
good as possible without affecting the content.
The filter will also filter out the drop-outs from
the RPM limiter used in the RPM ignition sys-
tem. Sometime there is a wish to actually see
the drop-outs in the Unipro Analyser program.
By enabling this setting, an extra unfiltered
RPM channels is logged beside the normal
RPM channel.
RPM BAR GRAPH MAX
When using the RPM bar graph on the run
mode 2 screen, you need to set the maximum
RPM value that could be shown. The bar graph
covers from 0 to 10000 RPMs. If you set the
maximum value to 13000, the RPM bar graph
will show values from 3000 to 13000 RPMs.
DRIVER SETUP
The driver menu contains all the settings
related to the driver.
All settings related to the driver are on the
driver menu screen.
Use the
up
( ) and
down
( ) buttons to
move around in the menu and press the
ok
button ( ) on the relevant line to change the
value. To accept the changes press the
ok
button ( ) again or press
back
( ) to cancel
the changes and revert to the original value.
NAME
To ease the identification of the files it is a very
good idea to enter the driver’s name. Please
enter the name as a normal text like described
next.
NATIONALITY
Text missing and feature not implemented yet.
Содержание UniGo One kit 1
Страница 1: ...UniGo One Laptimer User Guide W ORK IN PROGRESS RED TEXT M EANS NOT DONE SUBJECT TO CHANGE 24 12 2022...
Страница 6: ...VI This page was intentionally left blank...
Страница 10: ...10 I n t r o d u c t i o n Examples...
Страница 34: ...34 Setup mode C o n f i g u r i n g t h e L a p t i m e r...
Страница 55: ...55 I n d e x...
Страница 56: ...Unipro ApS Viborg Hovedvej 24 DK 7100 Vejle Denmark Tel 45 7585 1182 www uniprolaptimer com...