30
C o n f i g u r i n g
t h e L a p t i m e r
Setup mode
Delta time:
When passing the start/finish line
the delta time is shown. That is the time from
the lap just finished to the best lap time.
Max & delta:
Both “max. values” and “delta
time” is shown when passing the start/finish
line.
Min & max:
Both “max. values” and “delta
DATA HOLD TIME
When the last lap data is used, the display will
show the selected values for a certain time.
This time can be set from 2 to 20 seconds.
LAP TIME DISPLAY
Normally the lap time display is set to show
lap time. But UniGo is capable of calculating
the predictive lap time too. The predictive lap
time is calculated based on the actual lap time
at a given point of the track plus the rest of
the best lap. This way it will calculate the total
lap time based on the current pace and the
remaining of the best lap. It will typical vary
quite a bit at the start of the lap, and then get
more and more steady towards the end of the
lap.
Predictive lap time not implemented yet !
SPLIT TIME DISPLAY
When splits are being used the Laptimer can
do different things when passing a split point.
The options are “None”, “Split time”, “Delta
split time”. Here is a short explanation on what
the settings does.
None:
Nothing special is done when passing
a split point.
Split time:
When a split point is passed, the
split time and the split number is shown in the
display. The time and number is shown until
the next trigger is passed. When passing the
start/finish line, the Laptimer will show the lap
time and lap number instead.
Delta split time:
When a split point is
passed, the delta split time and the split
number is shown in the display. The delta split
time is the difference between the current split
time and the best split time. If the number
is negative the split time is better. The time
and number is shown until the next trigger
is passed. When passing the start/finish line,
the Laptimer will show the lap time and lap
number instead.
BETTER / WORSE FEEDBACK
MENU
The settings related to the better / worse
feedback is in a separate sub-menu.
UniGo will indicate if the lap time and split
times are better or worse compared to the best
time. The first green LED and the last red LED
is used for this feedback. The red LED is indi-
cating that the current time is worse compared
to the best and the green LED is indicating a
better time.
BETTER / WORSE TRIGGER
It is possible to configure how the better/
worse feedback should behave when passing
a trigger.
Off:
The two LEDs are not used for better /
worse indication.
Splits:
All split points are used for better /
worse feedback. When the start/finish line is
passed, the feedback is for “Split Last” and
not
the lap time.
Lap:
When passing the start/finish line, the
feedback is for the lap time. No feedback for
the split points.
Splits & lap:
All split points are used for
better / worse feedback, but when passing
the start/finish line, the feedback is for the lap
time. No feedback for “split last”.
LED ON TIME
The better / worse LEDs will stay on for this
amount of seconds after a trigger is passed.
Содержание UniGo One kit 1
Страница 1: ...UniGo One Laptimer User Guide W ORK IN PROGRESS RED TEXT M EANS NOT DONE SUBJECT TO CHANGE 24 12 2022...
Страница 6: ...VI This page was intentionally left blank...
Страница 10: ...10 I n t r o d u c t i o n Examples...
Страница 34: ...34 Setup mode C o n f i g u r i n g t h e L a p t i m e r...
Страница 55: ...55 I n d e x...
Страница 56: ...Unipro ApS Viborg Hovedvej 24 DK 7100 Vejle Denmark Tel 45 7585 1182 www uniprolaptimer com...