AP401FULL-HD_rev.09_UK
27
2.
STOP: stops the rotation of the motor.
3.
LIMITS: this command enables the following functions:
Disable Limits: clears the set limits from the motor’s memory.
Set East Limit: saves the limit position for rotation towards the east.
Set West Limit: saves the limit position for rotation towards the west.
Exit: exits the menu.
4.
PROGRAM.: this command enables the following functions:
Mem. Pos. PR (xx): allows for the position of the satellite dish to be saved within the
motor’s programs.
Recall Pos.: recalls the command from the motor’s program memory and starts the
positioning.
Exit: exits the menu.
5.
Default: this command enables the following functions:
Motor Reset: enables the rotation of the motor, bringing it back to the 0° position
Recalc. Sat. Pos.: recalculates the positions of the satellites saved within the motor’s
programs.
Exit: exits the menu.
To exit the menu and return to normal operating mode, press the
DiSEqC
button.
4.13.3.1.
USING THE DISEQC SCR FUNCTION
Turning the shaft encoder, move the cursor to DiSEqC SCR item. Press
ENTER
.
Turning the shaft encoder again, select the kind of LNB to drive between “mono feed” and
“dual feed”. Press
ENTER
to confirm. The screen displays the submenu to select one of the
four fixed frequencies and 1 user’s defined to use the SCR mode:
•
SCR A : 1210 MHz
•
SCR B : 1420 MHz
•
SCR C : 1680 MHz
•
SCR D : 2040 MHz
•
SCR E : USER
Turn the shaft encoder to select the desired frequency and press ENTER. The instrument
will go into SCR mode. The screen will indicate the polarity of the active satellite.
When using dual feed mode, the polarity indication is associated with either satellite 1 or 2.
The selections for mono feed mode are:
-
POL V (Vertical polarization)
-
POL H (Horizontal polarization)
The possible selections for dual feed mode are:
-
SAT 1 - POL V;
-
SAT 1 - POL H;
-
SAT 2 - POL V;
-
SAT 2 - POL H.