- 10 -
3.5 Electric wiring
(1) The pump rotates in the clockwise direction as seen from the front of the pump (level gauge
side).
(2)
An inlet is suitable for standards of EN60320.
(3)
Insert an including plug cord into an Inlet as shown in fig.8.
(4)
Select an power cord which suitable for the voltage class.
(5)
An overload protector (auto reset thermal protector) is incorporated.
(6)
End-user has to make provisions for the installation of the over current protection of the
power circuit.
A start mode of this motor is condenser start / operating method. The switching
of the start / operation reaches by electronic governor switch. When I apply
voltage of the inverter control because I use an electron element for electronic
governor switch, malfunction of the electronic governor switch occurs and causes
the motor stumbling-block. Please never apply voltage of the inverter control.
Unplug cords for power supply before connecting wires. Otherwise an electric shock
occurs.
GROUNDING INSTRUCTIONS
In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This pump
is equipped with a cord having a grounding wire with an appropriate grounding
plug. The plug must be plugged into an outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
If power code is not equipped (option) then appropriate grounding shall be
provided upon installation.
Improper installation of the grounding plug is able to result in a risk of
electric shock. When repair or replacement of the cord or plug is required,
do not connect the grounding wire to either flat blade terminal. The wire with
insulation having an outer surface that is green with or without yellow stripes
is the grounding wire.
Check with a qualified electrician or serviceman when the grounding
instructions are not completely understood, or when in doubt as to whether the
product is properly grounded. Do not modify the plug provided; if it does not
fit the outlet, have the proper outlet installed by a qualified electrician.
Note
Note
Warning
Warning
Warning
Содержание GLD-137CC
Страница 18: ...4 2 2 Dimensional drawing Fig 1 Dimensional drawing of GLD 137CC oil sealed rotary vacuum pump...
Страница 19: ...5 Fig 2 Dimensional drawing of GLD 202BB oil sealed rotary vacuum pump...
Страница 33: ...19 Fig 10 Pumping speed curve...
Страница 44: ...30 8 2 Disassembly drawing Fig 12 Disassembly drawing of GLD 137CC oil sealed rotary vacuum pump...
Страница 45: ...31 Fig 13 Disassembly drawing of GLD 202BB oil sealed rotary vacuum pump...