DC Power Supply [DPG-30R & DPG-MC60R, DPG-MC120R, DPG-MC240R]
4. Operation
34
4-1-3. System power each power setting
To match the system configuration of the power supply, rated output values for LEVEL
signal (DCV, DCI, DCP) and each monitor signal will change. Please refer to the table below.
Table.4-1 system power each power setting (DCV, DCI, DCP)
power setting (with master slave)
PSU
×1
×2
×3
×4
×5
×6
×7
×8
Total
Power
30kW
60kW
90kW
120kW
150kW
180kW
210kW
240kW
Output voltage
monitor signal
DCV
0 to 10V
0 to 1500V
Output current
monitor signal
DCI
0 to 10V
0 to 60A 0 to 120A 0 to 180A
0 to 240A
0 to 300A
0 to 360A
0 to 420A
0 to 480A
Output power
monitor signal
DCP
0 to 10V
0 to 30kW 0 to 60kW 0 to 90kW 0 to 120kW 0 to 150kW 0 to 180kW 0 to 210kW 0 to 240kW
Table.4-2 system power each power setting (LEVEL)
power setting (with master slave)
PSU
×1
×2
×3
×4
×5
×6
×7
×8
Total
Power
30kW
60kW
90kW
120kW
150kW
180kW
210kW
240kW
output
setting
voltage
LEVEL
0 to 10V
V control
(limit)
0 to 1500V
(0 to 1200V)
I control
(limit)
0 to 60A
(0 to 55A)
0 to 120A
(0 to 110A)
0 to 180A
(0 to 165A)
0 to 240A
(0 to 220A)
0 to 300A
(0 to 275A)
0 to 360A
(0 to 330A)
0 to 420A
(0 to 385A)
0 to 480A
(0 to 440A)
P control 0 to 30kW 0 to 60kW 0 to 90kW 0 to 120kW 0 to 150kW 0 to 180kW 0 to 210kW 0 to 240kW
* Please use it by
10.0Vmax P control mode, 9.17Vmax I control, 8.0Vmax V control when LEVEL signal.
If you exceed the above-mentioned level, will be stopped next to the ERROR output.
4-1-4. Timing chart for power supply system control
Turn on after full verifying safety. Turn the INTERLOCK signal off linked to DC FAIL.
INTERLOCK
To DC unit
On 4 seconds after INT ANSWER ON when no failure is occurring
Turn DC ON on after READY is on.
When READY is turned off, always turn off DC ON.
On within 100 ms after DC ON when READY is on. On within 100 ms when DC ON is on with READY on when FAIL is reset.
On when within the error range.
READY is turned off when FAIL occurs.
Turn on RESET signal for 100 ms or longer.
READY
RESET
DC FAIL
SETPOINT
OUTPUT
DC ON
Off when DC unit panel opens
From DC unit
From DC unit
From DC unit
From DC unit
To DC unit
To DC unit
INT ANSWER
From DC unit
On when INTERLOCK is on to DC unit and DC unit panels are closed
When INTERLOCK turned off
externally.
Figure 4-2 Power supply system operation timing chart