4.1
MAINTENANCE
MAINTENANCE
Prior to Cleaning
Every environment and application is different; therefore, UltraSource cannot provide
cleaning instructions to guarantee microbiological sanitation. UltraSource requests that the
owner of this machine consult with sanitation experts to review the unit working in their
particular environment to develop a robust cleaning schedule and methodology, followed by
bacterial testing to ensure satisfactory cleaning procedures are followed.
Cleaning Recommendations
Before cleaning the machine, turn power off; disconnect the main power, and lockout the
connection.
DANGER
Hazardous voltage.
Disconnect and lockout power before servicing machine or cleaning. Do not remove panels
unless power has been disconnected and locked out at risk of electric shock hazard.
Check with the detergent and sanitizer manufacturers that their products are compatible
with the listed materials.
CAUTION
Cleaning agents.
Do not get the cleaning agents in eyes, on skin, or on clothing. Always wear rubber gloves,
goggles, and protective clothing when contact is likely. Consult product manufacturer for
specific details.
Never hose down the machine. Damage caused by hosing or high pressure washing is not
covered under warranty.
1.
Filler Plates:
Remove filler plates. The filler plates are made from polyethylene. Clean,
sanitize, and dry. High pressure water spray can be used on the filler plates.
2.
Lid and Backup Strip:
The lid is constructed of acrylic. Use only nonabrasive soap and
water. Do not use window sprays or kitchen scouring compounds. The backup strip is
made of silicone. Clean, sanitize, and dry.
3.
Seal Bars:
Remove the seal bars by first lifting them up off of the guide rods. Remove
the wire connectors from the adapter clips on the seal bar and remove the seal bar from
the machine. The seal bars are made of aluminum and phenolic. Clean, sanitize, and
dry.
4.
Chamber and Base:
The chamber and base are made of 304 stainless steel. Clean,
sanitize, and dry, including under the seal bar bladder (not removable).
5. Clean under the machine.
6. Reinstall the seal bar.
7. Use bacteriological testing to insure cleaning process.