Think
UltraSource
First
. • [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 • 800.777.5624 • 816.753.2150
4.6
MAINTENANCE
MAINTENANCE
Supervisor Menu on Digital Panel (Continued)
Figure 4.5
# PROGRAMS: 10
SECURITY: NO
COOLDOWN: 4.0
TEST: YES
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
-
+
-
+
-
+
-
+
COOLDOWN is the time that the machine
waits after sealing the bag/pouch before
the seal bars retract. This allows time for
the actual seal to cool down and take a set.
The range is from 1 to 8 seconds.
Press the MENU key.
SECURITY can be turned on by selecting
YES. If security is on, the operator menu
will be read only and the operator will not
be able to change any settings.
Press the MENU key.
This is how you specify the maximum
number of programs that may be saved in
memory. Each program may have its own
set of unique parameters.
This range is from 1 to 10.
Press the MENU key.
If TEST is set to YES (using the UP arrow
key), the vacuum valve and vent valve may
be operated manually. The UP arrow key
activates the vacuum valve, the DOWN
arrow key activates the vent valve, and
pressing both at the same time turns them
both off. As you activate either valve, the
vacuum pressure is displayed.
Press the MENU key.
Содержание Ultravac 500
Страница 2: ......
Страница 69: ...9 ...
Страница 70: ...10 ...
Страница 72: ...12 13 ...
Страница 80: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Страница 81: ...22 ...