Think
UltraSource
First
. • [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
2.1
ST
ARTUP
Startup
Unpacking
1. Carefully remove crate from the skid.
2. Remove machine from skid.
3. Wipe down outside of the machine.
Power Requirements
The machine is available with 2 horsepower or 3 horsepower vacuum pumps.
The owner must supply the correct 3 phase or single phase power source in accordance
with the National Electric Code.
Grounding Instructions
The Ultravac
®
500 must be grounded. In the event of malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock. All
3 phase units are equipped with an equipment-grounding plug and the single phase units
are equipped with an equipment-grounding conductor cord. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
DANGER
Hazardous voltage.
Improper connection of the equipment-grounding conductor can result in a risk of electric
shock.
The equipment-grounding conductor outer surface is green with or without yellow stripes.
If repair or replacement of the cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal. Check with a qualified electrician or Ultravac
Services technician if the grounding instructions are not completely understood, or if there
is doubt as to whether the unit is properly grounded. Do not modify the plug provided with
the unit – if it will not fit the outlet; have a proper outlet installed by a qualified electrician.
Customer Voltage
Pump Motor Full Load Amps
Supply conductor shall have an
ampacity not less than 125% of
the Pump Motor Full Load Amps
230, 60 Hz, Single
Phase
13.5
230, 60 Hz, 3 Phase
10
380, 50/60 Hz, 3
Phase
6.3