Think
UltraSource
First
. • [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
4.3
MAINTENANCE
Reading the Indicators
If your machine is controlled by a digital control module (with touch pad), this design aids in
troubleshooting. The digital panel has indicator lights mounted on the front below the ON/
OFF switch. The indicator lights correspond to the operating devices and should turn on and
off in the following sequence when the machine lid is closed:
1.
Vacuum Pump [C-1]
2.
Gas Flush Valve [SOL-3] (Optional)
3.
Seal Bladder Valve [SOL-2]
(Stays on until completion of cycle)
4.
Seal Impulse Contactor [C-2]
5.
Ventilation Valve [SOL-1]
The device should be operating when the light is illuminated. If the lights illuminate in the
proper sequence, but there is still a problem, look for the problem in the operating device
itself. If the lights do not sequence properly, look for a problem in the control module.
Troubleshooting
Problem
Indications
Remedy
Machine will not start
Green power “ON” light not
lit when switch is turned on
Make sure that the power
requirements match those given
on the nameplate. Also, check
fuse F-2; replace if blown
Vacuum pump does not run
Make sure that the power
requirements match those given
on the nameplate
No vacuum
When lid is closed, indicator
light (VAC) is “OFF” on the
control module
Check lid switches LS-1 for proper
adjustment
Vacuum not pulling lid down Check intake screen in vacuum
pump hose barb for blockage,
pieces of bags, labels, bone, etc
Longer vacuum cycle times
Check intake screen in vacuum
pump hose barb for blockage
No gas flush (optional) If indicator light (GAS) is lit
Check for proper gas pressure
going into gas inlet
Check for proper operation of gas
flush valve (SOL-3)
If indicator light (GAS) is not
lit
Check gas flush potentiometer on
analog control module or possible
defective digital control panel
1. VACUUM VALVE [SOL-1]
2. GAS FLUSH VALVE [SOL-2] (OPTIONAL)
3. SEAL BLADDER VALVE [SOL-3]
(STAYS ON UNTIL COMPLETION OF CYCLE)
4. SEAL IMPULSE CONTACTOR [C-2]
5. VANTILATION VALVE [SOL-4]