UltraGlow G33R-1 Zero Clearance Rear Vent Direct Vent Gas Fireplace
21
LOG SET
INSTALLATION
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
operation.
Log Kit # 431-930 contains the following
pieces:
250
Vermiculite
Vermiculite
Vermiculite
The 3-digit numbers (i.e. 251) are molded into
the rear of each log.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care -
do not force into position.
2) Sprinkle the vermiculite around the fi rebox
base.
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 1/2 psig.
The manifold pressure is controlled by a regu-
lator built into the gas control, and should be
checked at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1)
Make sure the valve is in the "OFF" posi-
tion.
2)
Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide fl at screwdriver.
3)
Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
INSTALLATION
PILOT ADJUSTMENT
Periodically check the pilot fl ames. Correct
fl ame pattern has three strong blue fl ames:
1 fl owing around the thermopile, 1 around
the thermocouple and 1 fl owing across the
burner (it does not have to be touching the
burner).
Note: If you have an incorrect fl ame pat-
tern, contact your UltraGlow dealer
for further instructions.
4)
Light the pilot and turn the valve to "ON"
position.
5)
The pressure check should be carried out
with the unit burning and the setting should
be within the limits specifi ed on the safety
label.
6)
When fi nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
fl at screwdriver.
Note: Screw should be
snug, but do not over tighten.
S.I.T. Valve Description
1)
Gas
cock
knob
2)
Manual high/low adjustment
3)
Pilot
Adjustment
4)
Thermocouple
Connection
-
option
5)
Outlet Pressure Tap
6)
Inlet
Pressure
Tap
7)
Pilot
Outlet
8)
Main Gas Outlet
9)
Alternative
TC
Connection
Point
3) Place the Log 250 on the rear log support
pins with the fl at side to the back.
A) 250
Rear Log
902-250
B) 254
Middle Cross Log
902-254
C) 253
Front Left Cross Log 902-253
D) 251
Rear Left Log
902-251
E) 252
Front Right Cross Log 902-252
F) Embers
902-156
G) Vermiculite
902-179/21
NOTE: If you will be installing the optional
Brick Panels, install the Brick Panels
prior to installing the logs.
Incorrect fl ame pattern will have small, prob-
ably yellow fl ames, not coming into proper
contact with the rear burner or thermopile or
thermocouple.
D) 251
A) 250
C) 253
B) 254
E) 252