VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible
, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Required Parts:
Part #
Description
946-529 Co-linear
DV
Vertical
Termination
Cap
948-305
3" Flex - 35 ft.
946-563 Co-Axial to Co-Linear Adapter
Kit
which contains the following:
Co-linear Flex Adapter
Outer
Pipe
Inner
Pipe
Adapter
510-994 Rigid
Pipe
Adaptor
Alternate Approved Caps
980 Vertical
Termination
Cap
991 High
Wind
Cap
923GK 3" Co-linear Adapter with fl ashing
INSTALLATION
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
FPI Cabinet and/or Flat Wall Mantles
may be used in these applications en-
suring that clearances to combustibles
are maintained.