UltiMaker S7
Installation and user manual
6
Safe use information for UltiMaker materials.
UltiMaker materials can be printed safely without any
additional filtering using the recommended temperatures and settings in a well-ventilated area (minimum
refresh rate or AER of 1.8 for a room size of 30.6 m3). When multiple UltiMaker 3D printers are operated in a
contained environment, concentrations of UFPs and/or VOCs will increase. Depending on the specific situation,
please consider other safety measures, such as a separate filter, cabinet, and/or dedicated ventilation system.
Safe use information for third-party materials.
Make sure to check with your material supplier whether
additional risks and safety measures apply. Additional safety measures may be required for the safe usage
of such materials. Always take the relevant information provided by the supplier of third-party materials
into account for safe operation. Please check the safety data sheet of each specific material for information.
UltiMaker cannot be held responsible for any adverse effects from the use and/or performance of
third-party materials.
Magnetic field
Staticmagneticfieldhazard.
Due to the static magnetic field caused by the magnets in the printer, keep
a distance of at least 4 cm between any implanted electronic medical devices and implants containing
ferromagnetic materials.
Personal protective equipment
The following items are recommended for working safely with the UltiMaker S7, especially for performing
maintenance actions:
•
Tweezers.
These are required for safely removing material residue from the tip of the nozzle.
•
Pliers.
When cleaning the inside of the nozzle with the hot and cold pull procedure, hold the filament with
pliers to prevent damage to your hands in case the material breaks.
•
Thermal gloves.
It is recommended to wear thermal gloves while cleaning the nozzle as the nozzle will be hot
during these procedures.
1.4 Regulatory information
Electromagnetic compatibility
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules and the EMC Directive 2014/30/EU. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at their own expense.
EC declaration of conformity
UltiMaker S-line products, including the UltiMaker S7, are compliant towards the essential requirements and other
relevant provisions of the Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, RED 2014/53/EU, RoHS
Directive 2011/65/EU, and WEEE Directive 2012/19/EU.
A signed copy of the full EC declaration of conformity (English) can also be downloaded from
.