2.3.4 Stepper Motor Operation
To actuate a Stepper motorised drive it should be connected to an appropriate stepper motor
controller. All mating connectors are supplied to enable fabrication of custom connection cables.
Alternatively a complete solution and all relevant cabling are available from UHV Design.
Homing
– Best Practice.
If using a home sensor option then there are some rules that should be followed to
ensure precise and consistent homing or datuming.
Always approach the home sensor from the same direction
If approaching the home at high speed with a high load then the inertia may cause the
sensor to overrun. Best practice is to find the home, then drive off in the opposite
direction, and then creep back to the home sensor at a low speed. This will ensure a more
precise datum capture.
Содержание MD40 Series
Страница 41: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 41 of 56 Author N Carapiet Revision 1 1 3 1 3 Switch Pin Out...
Страница 43: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 43 of 56 Author N Carapiet Revision 1 1 3 2 3 Home Sensor Pin Out...
Страница 47: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 47 of 56 Author N Carapiet Revision 1 1 Drawings Base Drive...
Страница 48: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 48 of 56 Author N Carapiet Revision 1 1 Dual Shaft...
Страница 49: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 49 of 56 Author N Carapiet Revision 1 1 Pneumatic Drive...
Страница 51: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 51 of 56 Author N Carapiet Revision 1 1 Side Mounted DC Motor Options...
Страница 55: ...MD40 PRODUCT INSTRUCTION MANUAL MD40 Page 55 of 56 Author N Carapiet Revision 1 1 NOTES...