89
Alarm code
Alarm description
Alarm Response
0x09
Abnormal current
detection
Gripper speeding
0x0C
Power on the robotic arm again
and enable the gripper
0x0B
Gripper overcurrent
Re-enable the gripper.
Power on again and enable the gripper
Position command is
too large
0x0E
Please check if the location
setting value is too large
EEPROM read and write
error
0x0F
Power on again
Driver IC hardware alar
0x14
Power on again
Driver IC initialization
abnormal
0x15
Power on again
Position deviation is too
large
0x17
Please check if it is blocked or not,
and the position setting value is too large.
Gripper command
overrun
0X19
Please check the gripper command
Gripper position
overrun
0X1A
Please check the gripper position
Drive overload
0x21
Please check if the load is too large
motor overload
0x22
Please check if the load is too large
Drive-related error
0x24
Power on again
For alarm codes that are not listed in the above table: enable the robotic arm and
gripper. If the problem remains unsolved after power on/off for multiple times,
please contact technical support.