18
5.2.Emergency Stop Button
By pressing the emergency stop button of the controller, a command will be sent to the con-
troller for software deceleration to stop all activities of the robotic arm, plus clear all the
cache commands in the controller; the power supply for the robotic arm will be disconnect
within 300ms. Emergency stop should not be used as a risk reduction measure. When an
emergency occurs during the operation of the robotic arm, users can press the emergency
stop and the posture of the arm will remain at the moment when the button is pressed. The
emergency stop button is shown below:
Figure 5.6 Robot Joints
Joint 1
Joint 3
Joint 5
Joint 6
Joint 2
Joint 4