40
The digital output is implemented in the form of NPN. When the digital output is enabled,
the corresponding connector will be driven to GND. When the digital output is disabled, the
corresponding connector will be open (open/open).
Users must follow the electrical specifications set in section 8.5.1 ‘universal specification’.
The following example shows how to use the digital output, as the internal output is an
open-drain output, so you need to connect the resistor to the power supply according to the
load. The size and power of the resistor depends on the specific use.
Note: It is highly recommended to use a protection diode for inductive loads as shown
below.
8.5.3.Common Digital I/O Function
8.5.3.1.Configurable digital Output