I.

 

Turn on the Ultraprobe 15,000 

 

 

 

 

 

11 

II.    Home Screen 

 

 

 

 

 

 

 

11 

 

Main Screen (dB) 

 

 

 

 

 

 

12 

 

Setup Screen  

 

 

 

 

 

 

12 

 

dB/Temp 

 

 

 

 

 

 

 

12 

 

Valve (ABCD) Screen 

 

 

 

 

 

12 

 

Route 

 

 

 

 

 

 

 

12 

 
Setup Screens/Icons   

 

 

 

 

 

 

12 

 

Preferences   

 

 

 

 

 

 

12 

 

Info  

 

 

 

 

 

 

 

13 

 

Reset 

 

 

 

 

 

 

 

13 

 

Upgrades 

 

 

 

 

 

 

 

14 

 

Applications  

 

 

 

 

 

 

14 

 

Fields 

 

 

 

 

 

 

 

14 

Viewing and Selecting Icons   

 

 

 

 

 

14 

Using Screens 

 

 

 

 

 

 

 

14 

Using Main (dB) Screen 

 

 

 

 

 

 

15 

Using dB/Temp Screen 

 

 

 

 

 

 

16 

Using Temp & Emissivity Screen 

 

 

 

 

 

16 

Using Valve/Steam Screen 

 

 

 

 

 

 

16-17 

Using Spectra (FFT) Screens   

 

 

 

 

 

17 

Selecting Icons for Position on Displays  

 

 

 

 

18 

Storing a Record 

 

 

 

 

 

 

 

18 

Recording a Sound 

 

 

 

 

 

 

 

18-19 

Capturing the Spectra Screen Image 

 

 

 

 

 

19 

Entering Test Data 

 

 

 

 

 

 

 

19 

View Record  

 

 

 

 

 

 

 

19 

Viewing, Sorting a Route 

 

 

 

 

 

 

20 

Camera 

 

 

 

 

 

 

 

 

20 

Trigger Switch 

 

 

 

 

 

 

 

20 

Quick Change Battery  

 

 

 

 

 

 

20 

Wrist Strap   

 

 

 

 

 

 

 

21 

Headset Jack  

 

 

 

 

 

 

 

21 

Recharge Jack 

 

 

 

 

 

 

 

21 

Charging Pod 

 

 

 

 

 

 

 

21 

 
4.    User Instructions

 

Trisonic- Scanning Module 

 

 

 

 

 

21 

 

 

 

 

 

 

 

 

21 

 

Method of Airborne Detection 

 

 

 

 

 

21 

 

Headset   

 

 

 

 

 

 

 

21 

 

Rubber Focusing Probe 

 

 

 

 

 

 

21 

 

Long Range Module 

 

 

 

 

 

 

21 

 

Stethoscope Module 

 

 

 

 

 

 

22 

 

Stethoscope Extension Kit  

 

 

 

 

 

22 

 

RAM-MT Magnetic Transducer 

 

 

 

 

 

22 

 

Charging the UP15000 

 

 

 

 

 

 

22 

 

Warble Tone Generator 

 

 

 

 

 

 

22 

 

Charging the Warble Tone Generator 

 

 

 

 

22-23 

 

Helpful Hints 

 

 

 

 

 

 

 

23 

 

Using the SD card 

 

 

 

 

 

 

23 

 

Playing a Recorded S0nd   

 

 

 

 

 

23 

 

Auto Shutdown Battery Feature 

 

 

 

 

 

23 

 

Resetting the On Board Computer   

 

 

 

 

23 

Содержание Ultraprobe 15000 Touch

Страница 1: ...1 V 1 9 Instruction Manual ULTRAPROBE 15 000 TOUCH...

Страница 2: ...ery 7 BCH 15 Battery Charger 7 Battery Charger Pod 7 B Optional Accessories 8 CFM 15 8 UWC 15 8 DHC 2 Headphones 8 TFSM 8 TFCM 8 UFMTG 1991 8 WTG 2SP Warble Pipe Threaded Tone Generator 8 BCH WTG2 8 H...

Страница 3: ...ding a Sound 18 19 Capturing the Spectra Screen Image 19 Entering Test Data 19 View Record 19 Viewing Sorting a Route 20 Camera 20 Trigger Switch 20 Quick Change Battery 20 Wrist Strap 21 Headset Jack...

Страница 4: ...4 Alarm Enable Disable 23 Ultraprobe 15 000 Specifications 24 Instructions For Setting The Combination Lock On Carrying Case 26 Index 27 29 Appendix A Sensitivity Validation procedure 30 31...

Страница 5: ...TRASOUND TECHNOLOGY TRAINING Your Ultraprobe 15 000 has many applications ranging from leak detection and electrical inspection to mechanical analysis It may be used to analyze sounds and data view tr...

Страница 6: ...d is utilized as a waveguide in that it is sensitive to ultrasound that is generated internally such as within a pipe bearing housing or steam trap Once stimulated by ultrasound it transfers the signa...

Страница 7: ...UBBER FOCUSING PROBE The Rubber Focusing Probe is a cone shaped rubber shield It is used to block out stray ultrasound and to assist in narrowing the field of reception of the Trisonic Scanning Module...

Страница 8: ...ontact Module A contact probe for structure borne inspection that can be extended for hard to reach areas UFMTG 1991 The UFMTG 1991 is a multi directional warble tone generator It has a high power out...

Страница 9: ...s must be pressed firmly to turn the instrument ON ON OFF BUTTON Main Default Screen Spectral Analysis screen function Opens Camera for photos View a specific historical record Main Screen displays dB...

Страница 10: ...installed SD CARD AND SLOT When removing the SD Card while the REMOVE SD CARD Instrument is on open the Home Screen and Select this icon You will be prompted when to turn the instrument off NOTE Be s...

Страница 11: ...the arrows move up or down until Trig Laser ON OFF is shown Touch the box to select and exit LASER POINTER 8 Slide the Battery into the Handle until it Clicks in securely BATTERY 9 TEST MODULE RECEPTA...

Страница 12: ...by touching the test number Remove SD Card You must touch this icon BEFORE removing your SD Card II Before using the instrument become familiar with the various features and modes of operation You may...

Страница 13: ...stay on until either it is turned off set in suspend or the battery charge is depleted 9 Frequency Adjust An inspector might want to be sure the frequency is not changed during a route To lock the fr...

Страница 14: ...a language Restart your computer Then upload a route onto the SD card With the SD card in the Ultraprobe select Upgrade Language Applications b Generic Each application has unique data When an applica...

Страница 15: ...he sensitivity frequency record number and emissivity a To change the Frequency touch the kHz frequency when a highlight appears around the selected area then use the UP DOWN arrows to adjust b To cha...

Страница 16: ...reading or locate the Temp on off icon and touch it again to turn the temperature reading function back on 4 Temp Emissivity To test for Temperature only select this screen This is the only operating...

Страница 17: ...he blank B lines and the dB reading will populate that section c Touch valve test point C be sure the instrument is in active test mode Freeze the reading on the screen by releasing the trigger tap th...

Страница 18: ...ted Operating Screens b When through adjusting the settings or to exit back to the Spectra Screen select DONE c STOP START When the Spectra screen opens it will start to display sounds sensed by the U...

Страница 19: ...estarted the averaging process begins again 10 CAPTURING THE SPECTRA SCREEN IMAGE The Image of the selected spectra screen can be saved for viewing or entering in a report To capture the screen image...

Страница 20: ...m box at the desired zoom location The zoom level will be displayed to the left of the zoom box c To capture the image i Touch the View Photo icon and the image will be shown on the screen ii Touch th...

Страница 21: ...mum sensitivity S 70 constantly reducing the sensitivity and following the bar graph amplitude display to the loudest point If there is too much ultrasound in the area reduce the sensitivity place the...

Страница 22: ...test location 1 Plug recharger cable into recharger jack on the UP15000 and then plug the recharger into a wall receptacle TO CHARGE THE UP15000 2 Make sure that the LED on the charger is blinking wh...

Страница 23: ...4 Select PLAY 5 A window will open displaying two wave files one with a prefix of BL is the Baseline wav file the other with a prefix of SA is the current wav file 6 Touch the Next button to move to...

Страница 24: ...Ia Laser Product Europe Output 1mW Wavelength 640nm Class II Laser Product Memory 400 storage locations Battery Lithium ION Rechargeable Operating Temperature 32 F to 122 F 0 C to 50 C Outputs SD card...

Страница 25: ...206586 1297576 1881263 Meets and exceeds ASTM E1002 2005 requirements for Leak Detection 2562758 2689339 4416145 4823600 5955670 6122966 6339961 6341518 6415645 6655214 6707762 6804992 14 Hayes Street...

Страница 26: ...e case you will see a change lever Move this change lever to the middle of the lock so that it hooks behind the change notch picture 1 2 Now set your personal combination by turning the dials to the d...

Страница 27: ...7 BCH WTG2 8 Camera 11 Camera 20 Capturing The Spectra Screen Image 19 CFM 15 8 Charging Pod 20 Charging The UP15000 22 Charging The Warble Tone Generator 22 Contact Module 6 dB Temp 12 DHC 2 Headphon...

Страница 28: ...ge Battery 20 RAM RAS MT 7 Recharge Jack 20 Recording a Sound 18 Resetting The On Board Computer 23 Route 12 Rubber Focusing Probe 7 Scanning Module 6 SD Card 10 Selecting Icons for Position on Displa...

Страница 29: ...s 24 Ultraprobe Kit 5 Using dB Temp Screen 16 Using Main Screen 15 Using Screens 14 Using Spectra FFT Screens 17 Using Temp Emissivity Screen 16 Using the SD card 10 21 Using Valve Screen 16 UWC 15 8...

Страница 30: ...ation Chart 3 Plug in the Headphones and adjust the ear pieces so that they are opened up and place them on the test table 4 In your kit select the longest of the Stethoscope extension probe rods 5 Pl...

Страница 31: ...Validation Chart 2 Plug in the Headphones and adjust the ear pieces so that they are opened up and place them on the test table 3 Place the Warble Tone Generator flat facing up with the recharge jack...

Страница 32: ...32 14 Hayes Street Elmsford NY 10523 USA Tel 914 592 1220 Fax 347 2181 Email info uesystems com Web page http www uesystems com UP15M1010 2010 UE Systems Inc All rights reserved...