SARA-R4/N4 series - AT Commands Manual
UBX-17003787 - R09
22 GNSS
Page 240 of 307
Parameter
Type
Description
<antenna_status>
Number
Antenna status (0 - 4)
(3)
. For more details see the u-blox GNSS receiver protocol
specification
<jamming_status>
Number
Jamming status
3
. For more details see the u-blox GNSS receiver protocol
specification
22.16.4 Notes
• If AssistNow Online aiding data has been configured by means of the <aiding> parameter of
AT command, the +ULOC request using <sensor>=1 (GNSS receiver only) can provide a +UULOC URC
reporting a CellLocate solution (<sensor_used>=2). This can happen if:
o a GNSS fix is not available.
o the CellLocate solution is more accurate (i.e. CellLocate solution's uncertainty is better than the
GNSS's one).
• The <jamming_status> value must be ignored if the jamming is disabled through
• The <date>, <time>, <lat>, <long> values are not enclosed in double quotes in the URC.
22.17 Localization information request status unsolicited
indiULOCIND
+ULOCIND
SARA-R410M-02B SARA-R410M-52B
Modules
SARA-N4
Syntax
PIN required
Settings saved Can be aborted
Response time Error reference
Attributes
full
No
No
-
22.17.1 Description
Configures sending of URCs from MT to TE in the case of
operations. The URC provides the result of
the steps of an
operation.
22.17.2 Syntax
Type
Syntax
Response
Example
Set
AT+ULOCIND=<mode>
OK
AT+ULOCIND=1
OK
Read
AT+ULOCIND?
+ULOCIND: <mode>
OK
+ULOCIND: 1
OK
Test
AT+ULOCIND=?
+ULOCIND: (list of supported
<mode>'s)
OK
+ULOCIND: (0-1)
OK
URC
+UULOCIND: <step>,<result>
OK
+UULOCIND: 1,0
OK
22.17.3 Defined values
Parameter
Type
Description
<mode>
Number
URC configuration:
•
0 (default value): disabled
•
1: enabled
<step>
Number
Informs the user about the operation in progress:
•
0: network scan start
•
1: network scan end
•
2: requesting data to the server
•
3: received data from the server
•
4: sending feedback to the server
<result>
Number
Represents the result of the aiding operation:
•
0: no error