SARA-R4/N4 series - AT Commands Manual
UBX-17003787 - R09
5 Mobile equipment control and status
Page 36 of 307
5.9 Report mobile termination error +CMEE
+CMEE
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M
Modules
SARA-N4
Syntax
PIN required
Settings saved Can be aborted
Response time Error reference
Attributes
full
No
No
No
-
5.9.1 Description
Configures the formatting of the result code +CME ERROR: <err> as an indication of an error relating to the
functionality of the MT. When enabled, MT related errors cause +CME ERROR: <err> final result code instead
of the regular ERROR final result code. The error result code is returned normally when an error is related to
syntax, invalid parameters or MT functionality.
5.9.2 Syntax
Type
Syntax
Response
Example
Set
AT+CMEE=[<n>]
OK
AT+CMEE=2
OK
Read
AT+CMEE?
+CMEE: <n>
OK
+CMEE: 0
OK
Test
AT+CMEE=?
+CMEE: (list of supported <n>s)
OK
+CMEE: (0-2)
OK
5.9.3 Defined values
Parameter
Type
Description
<n>
Number
•
0: +CME ERROR: <err> result code disabled and ERROR used
•
1: +CME ERROR: <err> result code enabled and numeric <err> values used
•
2: +CME ERROR: <err> result code enabled and verbose <err> values used
5.9.4 Notes
• The following convention is valid:
Numeric error code Verbose error code
Description
3
"operation not allowed"
The MT is in a state which does not allow performing the
entered command.
4
"operation not supported"
The error result code is related to a parameter not covered by
the GSM/ETSI or u-blox specification