TOBY-L1 and MPCI-L1 series - System Integration Manual
UBX-13001482 - R04
Advance Information
Design-in
Page 72 of 90
2.15
Schematic for TOBY-L1 and MPCI-L1 series module integration
Figure 44 is an example of a schematic diagram where a TOBY-L1 series module is integrated into an application
board, using all the available interfaces and functions of the module.
4V0
GND
100nF
10nF
15pF
TOBY-L1 series
71
VCC
72
VCC
70
VCC
3
V_BCKP
23
RESET_N
Application
Processor
Open
Drain
Output
20
PWR_ON
100k
Ω
Open
Drain
Output
GND
GND
USB 2.0 Host
D-
D+
27
USB_D-
28
USB_D+
68pF
47pF
SIM Card
Connector
CCVCC (C1)
CCVPP (C6)
CCIO (C7)
CCCLK (C3)
CCRST (C2)
GND (C5)
47pF 47pF
100nF
59
VSIM
57
SIM_IO
56
SIM_CLK
58
SIM_RST
47pF
5
V_INT
ESD ESD ESD ESD
81
ANT1
87
ANT2
Primary
Antenna
TP
TP
TP
Secondary
Antenna
21
GPIO1
4V0
Network
Indicator
61
GPIO6
60
GPIO5
25
GPIO4
24
GPIO3
22
GPIO2
RSVD
RSVD
RSVD
RSVD
16
17
49
TP
TP
TP
Figure 44: Example of schematic diagram to integrate TOBY-L1 series module in an application board, using all the interfaces