5.2.3
Connecting to Wireless Communication Test Set
Wireless Communication Test Sets as Base Station simulators can be helpful with the ability to make protocol,
functional, throughput and RF measurements. To connect a TOBY-L1 or MPCI-L1 series modules to such a test
set that can support the module’s signaling and RF specifications, the commands listed in Table 28 are required
over the AT command user interface. Figure 49 demonstrates how the AT-commands sequence would appear,
when they are issued through a supported terminal.
Refer to the
TOBY-L1 / MPCI-L1 series AT Commands Manual
[3] for further details on the AT-Commands
described in Table 28.
Step
AT Command Syntax
Response
Description
1
AT%SETCFG="vzw_mode","0"
OK
Disable the IMS client.
2
AT%SETCFG="enable_test_mode","0"
OK
Disable test mode for conformance testing. By
default it is disabled.
This step is to ensure this mode is turned off.
3
AT%SETACFG=service.ECM.Enabled,true
OK
Enable the embedded connection manager.
4
AT%SETACFG=ecm.Mode.AutoConnectMode,true
OK
Enable “Auto Connect”.
5
AT%SETACFG=ecm.Mode.VzwImsTestMode,True
OK
Remove all the APNs in the PDP table and replace
it with a generic vzwinternet apn.
This will permit end to end data connectivity.
6
AT%SETCFG="USIM_SIMULATOR","1"
OK
Enable USIM Simulator embedded in the module.
7
ATZ
OK
Saves the changes made in above steps into the
NVRAM profile and resets the module.
Table 28: Configuring TOBY-L1 and MPCI-L1 series modules to connect with a Wireless Communication Test Set