38
Chapter 10: Tools
airFiber
®
AF5/AF5U User Guide
Ubiquiti Networks, Inc.
Chapter 10: Tools
Each tab of the airFiber Configuration Interface contains
network administration and monitoring tools. Click the
Tools
drop‑down list at the top right corner of the page.
Align Antenna
Use the
Align Antenna
tool to point and optimize the
antenna in the direction of maximum link signal. (See
“Using the airFiber Configuration Interface” on page
14
for more details.) The
Antenna Alignment
window is
designed to refresh every 250 milliseconds.
Chain 0/1 Signal Strength
Displays the absolute power
level (in dBm) of the received signal for each chain.
Note:
If “Overload” is displayed to indicate an
overload condition, identify and eliminate any
source of strong in‑band interference.
Remote Chain 0/1 Signal Strength
Displays the absolute
power level (in dBm) of the received signal for each chain
of the remote airFiber radio.
Max Signal
Displays the maximum signal strength (in
dBm). To adjust the range of the
Max Signal
meter, use
the slider or manually enter the new value. If you reduce
the range, the color change will be more sensitive to
signal fluctuations, indicating the offset of the maximum
indicator value and the scale itself.