UBI EasyCoder 601 XP – Service Manual Ed. 1
55
Chapter 8 Print Unit
Replacing the Sensors, cont'd.
To reassemble the LSS, proceed as follows:
• Thread the cables through the hole in the inner gable.
• Place the inner, lower corner of the bracket into the groove in the
carriage, almost at the innermost end.
• Tilt the bracket up at the outer end and push it inwards so the inner
notch in the bracket engages the carriage.
• Press down the outer end of the bracket, so the snap-lock engages
the outer notch.
• Press the bracket inwards as far as it goes and check that the
bracket is secured by the snap-lock.
• Connect the cable from the lower sensor to P54 (marked “LSS-
BOT”) and the cable from the upper sensor to P53 (marked
“LSS-TOP”) on the CPU board.
• Put back the guide plates, the electronics compartment cover, and
the power cord.
• Adjust the lateral position of the LSS.
8.6 Label Stop Sensor,
cont'd.
1.
2.
3.
Snap-Lock
Inner Notch
Outer Notch