UBI EasyCoder 601 XP – Service Manual Ed. 1
118
Chapter 16 Interfaces
Installation, cont'd.
• Remove the four #T10 Torx screws that hold the interface cover
plate above the Centronics connector on the printer's rear plate.
Remove the cover plate.
• Save the cover plate for possible later use. Keep the screws.
• If necessary, fit or remove circuits and straps to adapt the
Industrial Interface Board for the desired type of serial interface
as described in the chapter “Serial Port Configuration” later in
this booklet.
• Insert the Industrial Interface Board with the components side
facing right, as seen from behind. Check that the board fits into
the two square cut-outs on the left side of the slot.
• Attach the Industrial Interface Board to the printer's rear plate by
means of two of the screws left over when you removed the
original cover plate.
• Using the remaining two screws, attach the narrow cover plate
included in the delivery so it covers the right side of the slot.
16.4 Industrial Interface
Board,
cont'd.
#T10 Torx screws (4x)
Cover Plate
Industrial Interface Board