MAINTENANCE AND CLEANING
- Warning: Never use detergent, chemical
damage plastic parts.
- WARNING: Let the appliance cool down
completely before handling or cleaning.
- To prevent risk of fire or electrocution inside
the appliance.
- Clean the outside wall of the appliance by
rubbing it gently with soft, damp cloth, either
with or without soap.
- Regularly clean the air inlet and outlet vents
of the fan.
TECHNICAL CHARACTERISTICS
220-240V • 50Hz • 2000W
Environment friendly disposal
You can help protect the environment!
Please remember to respect the local
regulations: hand in the non-working electrical
equipments to an appropriate waste disposal
center.
4) after enter into standby mode, if the machine
cool down and:
Setting temperature – ambient temperature
>=2°C, the machine will wake up and
resume to heating.
If you want to cancel the setting
temperature, press “
” key to choose the
heating “ I ” or ” II ”, the product will work
without setting temperature. While the
display "°C" will go off.
After continuous
heating for 12 hours, the cool fan will work
for 30 seconds and enter into standby mode.
SET WEEKLY PROGRAM
(ONLY by remote control)
After complete setting of current TIME/DAY,
below is the steps to set weekly program:
1) Press ” “, the product enter into working
status.
2) Press “P“, lighted ”P“, it enter into weekly
program setting: See below: A
3) Press ”DAY“, the display shows d1~d7, set
to working day (Monday-Sunday: d1~d7).
Such as set Monday: see below: B
4) Press ”EDIT“, the display shows P1~P6 (for
each day, it can be set maximum 6 time
periods). Such as setting P1: see below: C
5) Press ”TIME/on“, the display shows 00”as
default. Press ”TIME/on““ continuously to
set the turn-on time. Such as set the turn-on
time 7:00am (Memo: the setting time 0-24
for choice) see below: D
6) Press ”TIME/off“, the display shows the
pervious step turn-on time by default. Press
”TIME/off“ continuously to set the turn-off
time. Such as set the shutdown time at
13:00pm (the display as figure), see below:
E
A
B
C
D
E
7) Press “+/−“ to setting the target temperature
(Temperature range 10-49°C),
8) Repeat steps 2-7 above, you can set the
whole weekly program, press ”OK“ to
confirm the setting.
9) To cancel the weekly function, press the "P"
again, the light "P" will go off. The weekly
program is off. The product will revert to the
previous function working status.
Note:
- After the above setting are completed and
P program is working, press ”DAY / EDIT /
TIME/on / TIME/off“ to check the setting time
of each day and time periods,
- The turn-on time periods 00~24hours,
cannot set to minutes ;
- The “TIME/OFF” can not be less than “TIME/
ON”;
- When the“TIME/ON” is the same as “TIME/
OFF”, the time period enter into standby
mode;
SET OPEN-WINDOW DETECTION
(ONLY by remote control):
1. Press “
“, the product enter into working
status. Heating for a moment untill stable.
2. Press ”
“ by remote control, light
“
/°C“ will on; The temperature display
”23” by default. Press “+/−“ to set target
temperature. During open-window detection
mode, once the ambient temperature drops
5-10°C within 10 minutes, then the product
will stop working within 30 minutes and enter
into stand by mode. Then press “
” to turn
on the product.
3. Press ”
“ again to turn off the open-
window detection, the light ”
“ will go
off and the product will resume to previous
working mode.
Below F is an example to set 23°C during
open-window detection.
4. When turn on at the same time for both
open-window detection and weekly program,
during the OFF period of weekly program,
the product doesn’t work. During the working
status of weekly program, the temperature is
subject to the setting temperature of open-
window detection. Below G is a example:
F
G
Note:
- Before turn on weekly program: it must set
day and time period, otherwise the weekly
default state is “00”, which does not work.
Model
FA-5571-3
Item
Symbol
Value
unit
Item
unit
Heat output
Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat
output
P
nom
2,0
kW
manual heat charge control, with integrated thermostat
[no]
Minimum heat
output (indicative)
P
min
0,0
kW
manual heat charge control with room and/or outdoor
temperature feedback
[no]
Maximum
continuous heat
output
P
max
2,0
kW
electronic heat charge control with room and/or
outdoor temperature feedback
[no]
Auxiliary electricity consumption
fan assisted heat output
[no]
At nominal heat
output
el
max
0,0
kW
Type of heat output/room temperature control
(select one)
At minimum heat
output
el
min
0,0
kW
single stage heat output and no room temperature
control
[no]
In standby mode
el
SB
0,000
kW
Two or more manual stages, no room temperature
control
[no]
with mechanic thermostat room temperature control
[no]
with electronic room temperature control
[no]
electronic room temperature control plus day timer
[no]
electronic room temperature control plus week timer
[yes]
Other control options (multiple selections possible)
room temperature control, with presence detection
[no]
room temperature control, with open window detection
[yes]
with distance control option
[no]
with adaptive start control
[no]
with working time limitation
[yes]
with black bulb sensor
[no]
Contact details
TIMETRON
Raimundgasse 1/8, A-1020 Vienna, Austria