RDU Mk2 Installation & Programming Manual
Document No: LT0499
System Specifications
Page 3-2
8 April 2015
Issue 1.02
3.1
GENERAL
3.1.1
FP0558 (AS1603.4), FP0785 (AS4428.1) 15U MAF RDU DESCRIPTION
Includes:
15U cabinet complete with MCP mounted externally
Controller/Display with FFCIF LCD & Keypad
MAF/PSU includes 7 relays, 3A PSU
Blanking plate covering 9U of 15U rack space.
The system can be expanded to include up to 64 zones of LED indicators using the 7U door
and 3 column LED display boards, or 160 zones using two 4U doors and 2 column LED
display boards. Refer to section 3.7 "Optional Additional Display" for detail on the extra
items required for this option. For New Zealand operation this does not include a Display
Extender Board.
Where more Display boards are required, they must be mounted externally via a suitable
mounting arrangement, e.g., extender cabinet. Any extra PSU loading due to additional
Display boards must be carefully considered when planning a system. Refer to section 5.3
for PSU loading and battery size calculations.
3.1.2
FP0585 (AS1603.4), FP0786 (AS4428.1) 8U MAF RDU
Includes:
8U cabinet complete with MCP mounted externally
Controller/Display with FFCIF LCD & Keypad
MAF/PSU includes 7 relays, 3A PSU
Blanking plate covering 4U of 8U rack space.
This RDU can accommodate up to 80 zones of LED indication using the ME0457 4U door
and up to 5 x FP1002 16 zone LED Display Boards. An NZ Display Extender Board cannot
be fitted.
3.1.3
FP0559 (AS1603.4) & FP0787 (AS4428.1) WALL-MOUNT SLIMLINE RDU
Includes:
Wall mount low profile cabinet
Controller/Display with FFCIF LCD & Keypad
Note
16 Zone LED Display boards can be added externally with an optional Display Extender
Board (NZ), if a suitable mounting arrangement, e.g., extender cabinet is provided. The non-
MAF slim-line RDU is line powered from the FIP, thus any extra PSU loading due to
additional Display boards must be carefully considered when planning a system.
3.1.4
FP0772 (AS1603.4) & FP0788 (AS4428.1) FLUSH-MOUNT SLIMLINE RDU
Includes:
Flush-mounted cabinet
Controller/Display with FFCIF LCD and keypad
Note
16 Zone LED Display boards can be added externally, with an optional Display Extender
Board (NZ), if a suitable mounting arrangement, e.g., extender cabinet is provided. The non-
MAF RDU is line powered from the FIP, thus any extra PSU loading due to additional
Display boards must be carefully considered when planning a system.
Содержание RDU Mk2
Страница 58: ...RDU Mk2 Installation Programming Manual Document No LT0499 Programming Part 1 Page 6 4 8 April 2015 Issue 1 02...
Страница 59: ...Document No LT0499 RDU Mk2 Installation Programming Manual Programming Part 1 Issue 1 02 8 April 2015 Page 6 5...
Страница 61: ...Document No LT0499 RDU Mk2 Installation Programming Manual Programming Part 1 Issue 1 02 8 April 2015 Page 6 7...
Страница 105: ...Document No LT0499 RDU Mk2 Installation Programming Manual Programming Part 2 Issue 1 02 8 April 2015 Page 7 9...