1. Connect to the CORIOmatrix via IP (each application has its own methodology of
con- figuring a connection - for assistance, see the documentation provided with that
program).
2. When you are connected, you will receive the following from the CORIOmatrix:
3. Log in by typing the following:
login(admin,adminpw)
and press
Return
or
Enter
.
(If you have changed the administrator password, use the appropriate password in
place of the text
adminpw
above.)
4. In the command line in your terminal application, below the words
"!Info : User
admin Logged In
", type the command to change resolution for the appropriate
output slot. In the example below, the monitor card is in slot 6 and we are using
output 1, changing the resolution to the monitor's default of 720x576p50. Replace the
slot and output number and resolution with the appropriate information for your
configuration:
slot6.out1.resolution = 720x576p50
5. After typing this and pressing return, the system will return a line starting with
!Done
.
6. To save this change, type
System.SaveAllSettings()
and press
Return
or
Enter
. The system returns
"!Done
System.SaveAllSettings()
". At thispoint you can disconnect from the
command-line connection and the monitor card will be using the resolution you just
configured.
Содержание C3-440
Страница 3: ......
Страница 19: ...tvOne Safety Instructions 11...
Страница 26: ...18 Introduction Configure Connection via Serial on page 29...
Страница 29: ...tvOne Introduction 21...
Страница 36: ...28 Introduction...
Страница 39: ...tvOne Getting Started 31...
Страница 51: ...tvOne Settings 43 Configure Connection via Serial on page 29...