202
Resolution Editor Guide
Read Output Resolution
Read which resolution is currently set for an output.
Command
Slots.Slot16.Out1.Resolution
(In this case, Slot 16 and Out 1 are used as an example - any valid slot number and output
number can be used in that context.)
Description
Reads the resolution currently set for an output.
Example
Slots.Slot16.out1.Resolution
Slots.Slot16.out1.Resolution = NewCustomResolution
!Done Slots.Slot16.out1.Resolution
Default
1280x720p60
Notes
If the properties of the Custom Resolution are changed, then the resolution will be reapplied
on the output and the connection to the output device will be renegotiated.
If the
Name
of a Custom Resolution is changed, then the output will return to its default and
you will need set the output to the new Custom Resolution
Name
.
If more than one Custom Resolution has the same name, when you set a Custom
Resolution of that name to an output, unexpected behavior may result.
Custom Resolutions cannot be applied to an SDI output.