Menus”. Turn the function ‘On”, exit the Systems menu and return to this
menu structure
.
The Resolution Database is used by your unit to identify any incoming video
signal and is also used to create an output resolution. It is therefore a very
important part of the unit’s infrastructure.
Important Cautionary Information
DO NOT ADJUST THESE ITEMS UNLESS YOU’RE CERTAIN YOU KNOW
WHAT YOU’RE DOING! THE ONLY METHOD TO UNDO CERTAIN
CHANGES IS TO UPDATE THE FIRMWARE.
TRY USING THE AUTOSET, SHRINK, SHRINK POS, TL & BR
ADJUSTMENTS FIRST.
Making adjustments here risks creating a non-standard resolution that is not
displayable on a monitor. The resolutions and values within the database are
industry standards and should not normally be altered by the user. That said,
there might be times when it is necessary to create a custom resolution with
specific parameters. If circumstances require you to make such a change,
please read the following specific notes:
1. Any changes made to this database take effect instantly and are also
stored immediately in non-volatile memory.
2. Since this database is used for both input and output image processing,
altering a resolution that is used for both (e.g. 1024x768 input and
1024x768 output) may give undesired effects.
Change the value to select resolution you want to alter.
Typically, the image number currently being used for input
or output would be already be selected otherwise
immediate feedback to your changes will not be available
via your monitor.
This adjustment specifies whether the image is interlaced or progressive
scan. It toggles simply On or Off, so there are no flashing brackets.
Course Frequency Adjust
800 x 600 60 Hz
Image to adjust [ 17]
800 x 600 60 Hz
Interlaced [ Off]
800 x 600 60 Hz
H.freq.crse [37.879] kHz