C2-7000 S
ERIES
O
PERATION
M
ANUAL
53
8.12
Items Associated with the Adjust buttons group
This menu group is only available for units with programmable front panel
buttons.
The Adjust Buttons sub menu allows the reassignment of the factory default
button associations. For instance, if you do not want button 3 to be associated
with RGB input number 1, you can redirect the button to another input or
feature.
You are strongly cautioned NOT to change the default assignments for
Window / Output switching (usually the left-hand button). To do so may make
control of your unit via the front panel extremely cumbersome.
To change a button assignment, change the button number to match the one
to alter, and then choose the new button assignment.
Once altered to your new assignment, it is recommended that you store your
new settings.
8.13
Items associated with the Adjust ethernet group
(Please note that not all units have this sub-menu.)
Your unit can be remotely controlled via its RS-232 serial port, but some units
can also be controlled via a Local Area Network using the Ethernet connector.
This provides TCP/IP communications to and from the unit using a custom
protocol.
The Adjust Ethernet Menu Group allows the setup of the Ethernet addressing
parameters such as IP address and Default Gateway. Access the Adjust
ethernet sub-menu and the following adjustments will be possible:
This parameter has three possible states: On, Off and Auto. On and off
manually control the Ethernet capability of the unit. When in Auto mode, if a
valid Ethernet connection is present, remote control of the unit will
Adjust ethernet
IP enabled [Auto]
Adjust buttons
Button [ 1] = Toggle ABZ
Adjust buttons
Shift [ 1] = Toggle 12