33
English
Phase 10
21) Dry phase begins: hot air is blowed inside the
tank at a presetted temperature and keep for the
presetted time. Phase not present in the version
without drying.
Fig. 18.22
22) End of the «STANDARD» cycle. Open the door and
remove the basket.
Fig. 18.23
If, for any reason, it is necessary to interrupt the cycle,
simply hold down the RESET key for a few seconds until
an audible alarm (buzzer) is heard and an alarm screen
appears on the display with the message:
«WARNING.
DISINFECTION CYCLE INTERRUPTED»
.
Once the problem is resolved, resume the cycle from
the beginning. If the problem cannot be solved, contact
the technical assistance.
6.6.4 Alarm messages
The machine is equipped with an alarm system that
indicates malfunctions detectable with an audible
signal (buzzer), a screen on the graphic display of the
control panel and a red led light in the camber.
The alarms, description and possible solution are listed
below.
At first the image concerning the alarm is displayed (for
5 seconds); then the alarm description is displayed (for
10 seconds).
The image and text alternate until the alarm is reset.
Fig. 19
6.6.5 User settings menu
Start screen
Fig. 20.1
To access the settings menu the procedure is as follows:
Open door -> PRG for 5 seconds -> Insert password.
The keys and their operation are shown below,
contextualised according the menu in which you are
located:
- Use P1 and P2 to navigate up and down the menu.
- Press START to access the entry of the menu selected.