AIR-WATER RADIATOR
This system is an air-cooled version with a cooling water total recovery system. A centrifugal pump circulates the cooling water
from the SDV vacuum pump to a radiator-fan unit. A flow indicator, flow switch on the cooling water supply line and temperature
guage (or switch) at the cooling water discharge line should be installed to monitor the adequacy of the colling water flow and the
cooling water discharge temperature.
For SDV-200 and larger-sized pumps, the cooling water circuit is extended to the process exhaust silencer. For SDV-120, silencer is
not jacketed, hence, cooling water circuit is not extended to the process exhaust silencer.
Figure 3. Typical Process and Inlet Discharge for SDV-120 with fan-cooled, re-circulated cooling water system
Figure 4. Typical Process and Inlet Discharge for all other SDV models with fan-cooled, re-circulated cooling water system