19
VACUUM SYSTEM CHECKLIST
CHECK POINT
CHECK
Before
Operation
Opening Cooling water supply valve. Is flow correct?
Close vacuum suction line.
Open Discharge line.
Check lubricant color and level. Is it acceptable?
Check Belt Tension (for V-belt type only)
Run vacuum pump for a few minutes before opening the Suction line.
During
Operation
Check vacuum level in full vacuum. Is it normal?
Check electric power condition (Voltage & Amperage) in full vacuum. Is it acceptable?
Any abnormal noise?
Check operation temperature. Is it normal?
Check lubricant color and level. Is it acceptable?
Stopping
Run vacuum pump for a few minutes after closing the suction line.
If foreign material is introduced inside of the vacuum pump, clean it with cleaning fluid.
Make sure that the Suction & Discharge line is closed.
Make sure the power supply is cut off.
SPECIAL TOOL LIST
DESCRIPTION
SPECIFICATION
MATERIAL
SDV-120
SDV-320
SDV-430
SDV-800
SDV-1500
SDV-2700
1 Bearing Pusher
3206/NJ206
Al bar
3208/NJ208
6207
Al bar
3308/6308
6207, NJ208
Al bar
3309/NJ309
3308/6308
Al bar
3216/2216
6314
Al bar; 2 ea
PTFE
PTFE
Aluminum
2 Mech. Seal Pusher
Special
Aluminum
3 Lip Seal Puller
Lip Seal Pusher
Consult factory
PTFE
4 Bearing Holder
Puller Assy
Consult factory
5 Hook Spanner
45/50
58/62
68/75
110/115
6 Feeler Gauge
(4”, 12”)
150 MZ
172 ME
7 Hex Wrench Fox
5 mm * 160mm
8mm * 230mm
8 Clamp Bolt Set
M8 * 55L
M8 * 55L
M10 * 150L
M12 * 160L, 2 ea
M8 * 100L
M8 * 100L
M8 * 150L
M12 * 130L, 2 ea
S45C
M8 * 150L
M10 * 100L
M10 * 270L
M12 * 70L, 4ea
M8 * 200L
M8 * 200L
M10 * 200L
M8 * 270L
Bolt (225L), 2 ea
9 “T” Wrench
6mm
“L” wrench
14 mm
10 “L” Wrench Set
In mm unit
11 Hammer (Rubber)
E-060
12 Torque Wrench
450-QLK
1400-QLK 1/2”
13 Tool Box
500 * 230 * 240
14 Removable Tapered
Slip Sleeve
Consult factory
15 Special Tool for push
sleeve installation
Consult factory
Содержание KINNEY SDV SDV-120