background image

S2

S2

S1

S2

S2

S2

(3 sec.)

S1

S1

S1

S1

S2

S2

S2

S1

(3 sec.)

Start

End

S2

S2

S2

S2

S1

S1

S1

S1

S1

S2

S2

10

3

 Fig. 

3

Id

tb

nt

F-0

Fu1 

Ud 

Od 

UdOd

Uof1

Uon1

Oon1

Oof1

tof1   

 

 

 

s

Fu2 

Ud 

Od 

UdOd 

Alr

Uof2

Uon2

Oon2

Oof2

tof2   

 

 

 

s

ICM 

off 

Br 

Sh 

BrSh

Loc 

off 

L1 

L2 

L12

Sud   

 

 

 

s

dS  

dSon  

dSof

td      

 

 

 

s

Soft

Messstelle:
Measuring point:
Point de mesure:

   MK21-122Ex0-R

   MK21-122-R

15

13

11

9

10

16

12

14

4

3

7

6

1

8

2

5

[EEx ia] IIC

Pwr 1

2

S1

S2

MK21-122Ex0-R

15

13

4

3

7

6

1

8

2

5

11

9

10

16

12

14

Pwr 1

2

S1

S2

MK21-122-R

 Fig. 

1

 Fig. 

2

2 /0207

Eingestellte Parameter:
Adjusted parameters:
Paramètres programmés:

MK21-122Ex0-R/MK21-122-R

Parameter – Einstellmöglichkeiten 

siehe Seiten 4 u. 5

Parameter selection possibilities 

see pages 4 and 5

Paramètres – Possibilités de sélection 

voir pages 4 et 5

Содержание MK21-122Ex0-R

Страница 1: ...N 60947 5 6 NAMUR 1 2 Connection of external signal sources 5 30 VDC 3 4 Potential free pulse output for connection of further sginal processors 30 V 10 mA 7 8 activation of start up time delay functi...

Страница 2: ...essstelle Measuring point Point de mesure MK21 122Ex0 R MK21 122 R 15 13 11 9 10 16 12 14 4 3 7 6 1 8 2 5 EEx ia IIC Pwr 1 2 S1 S2 MK21 122Ex0 R 15 13 4 3 7 6 1 8 2 5 11 9 10 16 12 14 Pwr 1 2 S1 S2 MK...

Страница 3: ...et S2 permettent de program mer les param tres individuels Le proces sus est visualis en fig 3 Les param tres sont m moris s m me en cas d une panne d alimentation D abord le param tre d sir est s lec...

Страница 4: ...f1 switch off threshold for underspeed monitoring if the speed drops below the adjusted value relay 1 is de energised Uon1 switch on threshold for underspeed monitoring if the speed exceeds the adjust...

Страница 5: ...d off without locking L1 locking of relay 1 only L2 locking of relay 2 only L12 locking of relay 1 and 2 Sud Start up time delay in seconds Fig 4 after activating the start up time delay those relay o...

Страница 6: ...up time delay may not be connected to non safe circuits General information on rotational speed monitoring Mechanical contacts are frequently subject to contact bounce Thus they are only suited for r...

Страница 7: ...unique de circuits de courant s curit intrins que des circuits non s curit intrins que ne permet plus un fonctionnement ult rieur comme mat riel lectrique s curit intrins que Pour la r alisation de ci...

Страница 8: ...t er klassificeret som et tilh rende apparat og m ikke installeres i Ex omr det Apparater i kategori 3 kan installeres i zone 2 Bem rk venligst s rlige oplysninger Alle nationale og internationale god...

Отзывы: