LEADING JET TURBINE Co., Ltd. ATJ TURBINES
27
Maintenance and repair work
ATJ turbines only need little maintenance under normal operating
conditions.
Some points must be considered to guarantee faultless operations of the
engine.
This includes regular cleaning and inspection.
Dirt and grease deposit can cause slippage of the starter clutch. If this
happens, clean the O-ring and the compressor nut with a degreaser like
alcohol.
Fuel tube and filter between the pump and the turbine should be cleaned
every 5 hours of operation.
Do this very carefully and make sure that no dirt will enter the fuel supply
tube. Destruction of the turbine could result!
Make sure fuel system no leaking.
Cover the intake and nozzle areas when the turbine is not in use.
Keep the turbine in a dry and dust-free environment when it is not used for a
longer time.
Check the battery condition regularly.
Your turbine maintenance interval is at 25 hours.
After this time as well as after a special event (crash, FOD.. etc.) the turbine
should be returned to the factory service.
Repair and maintenance work which include the disassembly of the turbine
must only be performed by professional personnel.
Please contact Leading Jet Turbine Co., Ltd with all service related
questions.
Maintenance and repair work performed by non authorized personnel will
void the warranty.