23
3.
: Selection of stop mode: In case of limit switch
SLOW/FAST default: SLOW
Select from the FAST (Sudden stop) or SLOW (Deceleration stop) how to stop when
it detects a limit switch
.
4.
: Selection of stop mode: In case of push button. (Panel operation)
SLOW/FAST default: SLOW
Select from FAST (Sudden stop) or SLOW (Deceleration stop) how to stop when
you push the STOP button in local mode.
5-5 Page5 REL/ABS/SCAN PRESET data setting
Also in the “mode display screen”, settings on this page is available.
1.
: SETUP channel selection
Same as Page 1.
2.
: REL mode set value
Setting range:
-2,147,483,647 ~ +2,147,483,647
Initial value: +10,000
Set the pulse value that relative movement when you press the START button in
local mode.
3.
: ABS mode set value
Setting range:
-2,147,483,647 ~ +2,147,483,647
Initial value: 0
Set the absolute movement of the pulse value when you press the START button in
local mode.
4.
: SCAN mode set value
Setting range:
-2,147,483,647 ~ +2,147,483,647
Initial value: 0
Set the value to be preset when you press the PRESET button in local mode.