In order to power on the camera, turn on the power switch which is available on the interface unit (Figure 2-
9).      

 

 

 

 

 

 

 

 

Figure 2:

 MR conditional Box type video camera installation diagram.  

4. Maintenance and Disposal  

4.1 Cleaning Information  

Dust and other matter that collect on the camera may eventually degrade image quality. Such matter should 
be removed from the top of the camera with a damp cloth.   

 

Warning 

 
Unplug all power connections before cleaning.  
 
 
 

4.1.1. Monitor Surface  

Dampen  (do  not  saturate)  a  clean,  lint-free  cloth  with  environmentally  friendly  glass  cleaner.  The  cleaner 
contains spirit as an active substance (up to 98%) and tensides, which can be biologically recycled. Cline the 
monitor screen using circular motions with the cloth to avoid streams. Remove fingerprints, grease, dirt, and 
dust. Carefully dry the screen with a second, lint-free cloth.  

4.1.2. Camera Surface and wires  

Use a cloth with disinfectant to clean the camera body and wires. Remove fingerprints, dirt, grease and dust. 

 

1. MRI Camera 

 

2. Video signal 
cable 

 

3. 9 Pin cable  

 

4. BNC Filter  

 

5. 9 pin filter 

 

2. Video signal 
cable 

 

3. 9 Pin cable  

 

Power Outlet   

 

6. Interface Box   

 

2. Video signal 
cable 

 

7. Video converter unit 

 

8. Monitor  

 

Magnet Room  

Cabinet Room  

Operator Room  

9. Power Switch 

 

Содержание T-290

Страница 1: ...4 Cad No 48 Yenimahalle Ankara TURKEY Tel 90 3122650096 info troykamed com www troykamed com T 290 MRI Conditional Box Camera Op Man Pub 022018 Pub No 0 Rev 0 OPERATORS MANUAL T 290 MRI Box Camera MRI...

Страница 2: ...85 2016 To ensure that you obtain maximum benefit from the T 290 MRI Box Camera please take a few minutes to read the enclosed information regarding operation service and maintenance After reading thi...

Страница 3: ...able risks to the patient medical staff or other persons within the MR environment 1 2 General Safety Information and Intended Use The MRI Box camera must only be operated by personnel property traine...

Страница 4: ...he Box camera possible electric shock or fire Don t handle the power cable with wet hands High voltages present could cause lethal electric shock Warning Should any foreign substances enter the device...

Страница 5: ...elds inside the magnetic room have the potential to dislodge items at high velocities and can result in serious injury or death Caution For questions regarding installation procedures or technical sup...

Страница 6: ...se consult your Troyka Med Sales or Service office Always use the power supply cord supplied in the original shipping carton If the enclosed power cord could not be used due to a different standard in...

Страница 7: ...d to view patient in MRI scanner or overview MRI room The T 290 MRI Box Camera System is designed to be MRI conditional and is manufactured and tested to the highest standards The camera system is des...

Страница 8: ...7 2 3 5 85 Weight 520 g 3 4 Installation 3 4 1 Installation Diagram of MRI Video Camera in Magnet Room A representative drawing is showing the layout plan of the MRI video camera is given in Figure 2...

Страница 9: ...ctions before cleaning 4 1 1 Monitor Surface Dampen do not saturate a clean lint free cloth with environmentally friendly glass cleaner The cleaner contains spirit as an active substance up to 98 and...

Страница 10: ...Troyka Med Inc IOSB Mah 2284 Cad No 48 Yenimahalle Ankara TURKEY Tel 90 3122650096 info troykamed com www troykamed com T 290 MRI Conditional Box Camera Op Man Pub 022018 Pub No 0 Rev 0...

Отзывы: