T-290 MRI Conditional Box Camera Op. Man. Pub. 022018 Pub. No: 0 Rev:0  

Introduction 

 

Thank you or purchasing the T-290 MRI Conditional Box Camera. This product is manufactured and 
tested to the highest standards and is guaranteed MR Conditional up to 3 Tesla.    

This product is manufactured by Troyka Med Inc. at our factory based is Ankara, Turkey, to BS EN 
ISO 13485:2016   

To  ensure  that  you  obtain  maximum  benefit  from  the  T-290  MRI  Box  Camera,  please  take  a  few 
minutes  to  read  the  enclosed  information  regarding  operation,  service  and  maintenance.  After 
reading this manual, store it in a safe place for future reference.  

If  you  have  any  problems  in  the  meantime  or  would  like  any  advice  about  this  or  any  other  MR 
products from the Troyka Med range, please contact us at the following address 

 

 

Troyka Med Inc. 

Tel:  

 

+90 312 2650096 

E-mail:  

[email protected] 

Website:  

www.troykamed.com 

 

 

 

 

Protect from 

direct sunlight 

 

Protect from rain and 

humidity 

 

MRI conditional up to 3 Tesla 

 

Read user manual 

 

Manufacturer 

 

ISO13485 

ISO 9001 

Class I medical devises 

 

 

 

Содержание T-290

Страница 1: ...4 Cad No 48 Yenimahalle Ankara TURKEY Tel 90 3122650096 info troykamed com www troykamed com T 290 MRI Conditional Box Camera Op Man Pub 022018 Pub No 0 Rev 0 OPERATORS MANUAL T 290 MRI Box Camera MRI...

Страница 2: ...85 2016 To ensure that you obtain maximum benefit from the T 290 MRI Box Camera please take a few minutes to read the enclosed information regarding operation service and maintenance After reading thi...

Страница 3: ...able risks to the patient medical staff or other persons within the MR environment 1 2 General Safety Information and Intended Use The MRI Box camera must only be operated by personnel property traine...

Страница 4: ...he Box camera possible electric shock or fire Don t handle the power cable with wet hands High voltages present could cause lethal electric shock Warning Should any foreign substances enter the device...

Страница 5: ...elds inside the magnetic room have the potential to dislodge items at high velocities and can result in serious injury or death Caution For questions regarding installation procedures or technical sup...

Страница 6: ...se consult your Troyka Med Sales or Service office Always use the power supply cord supplied in the original shipping carton If the enclosed power cord could not be used due to a different standard in...

Страница 7: ...d to view patient in MRI scanner or overview MRI room The T 290 MRI Box Camera System is designed to be MRI conditional and is manufactured and tested to the highest standards The camera system is des...

Страница 8: ...7 2 3 5 85 Weight 520 g 3 4 Installation 3 4 1 Installation Diagram of MRI Video Camera in Magnet Room A representative drawing is showing the layout plan of the MRI video camera is given in Figure 2...

Страница 9: ...ctions before cleaning 4 1 1 Monitor Surface Dampen do not saturate a clean lint free cloth with environmentally friendly glass cleaner The cleaner contains spirit as an active substance up to 98 and...

Страница 10: ...Troyka Med Inc IOSB Mah 2284 Cad No 48 Yenimahalle Ankara TURKEY Tel 90 3122650096 info troykamed com www troykamed com T 290 MRI Conditional Box Camera Op Man Pub 022018 Pub No 0 Rev 0...

Отзывы: