5  MRI BNC filter  

 

6  Box camera interface box (with 30 m coaxial cable)

 

Please contact for other length requirements.

 

 

 

7  Power cable 

 
 
 

 

8    DVR unit    

 

9  Monitor: 17‘’ LED monitor 

Please contact for other options.

 

 
 
 

 

Table 1:

 MRI Box camera system list of components 

3.2 System Overview  

Our MRI compatible cameras are designed to view and record video images of objects in an MR scanner. The 
camera can be used to view patient in MRI scanner or overview MRI room.  

The T-290 MRI Box Camera System is designed to be MRI conditional and is manufactured and tested to the 
highest standards. The camera system is designed to be used with all MRI scanners up to 3 Tesla magnetic 
field strength.  

A picture of MRI conditional Box camera is given in Figure 1. The camera can be used both on the wall or 
ceiling mount position and the angle of view could be adjusted to any possible position. The camera has 5-50 
lens. This high focus capability of the camera gives users an ability to focus camera to any desired position 
even from long distance. Embedded IR LED provide high image quality even in a low light environment. 2 MP 
sensor provides high image quality.  

 

Figure 1:

 MRI Conditional Box Camera. 

Содержание T-290

Страница 1: ...4 Cad No 48 Yenimahalle Ankara TURKEY Tel 90 3122650096 info troykamed com www troykamed com T 290 MRI Conditional Box Camera Op Man Pub 022018 Pub No 0 Rev 0 OPERATORS MANUAL T 290 MRI Box Camera MRI...

Страница 2: ...85 2016 To ensure that you obtain maximum benefit from the T 290 MRI Box Camera please take a few minutes to read the enclosed information regarding operation service and maintenance After reading thi...

Страница 3: ...able risks to the patient medical staff or other persons within the MR environment 1 2 General Safety Information and Intended Use The MRI Box camera must only be operated by personnel property traine...

Страница 4: ...he Box camera possible electric shock or fire Don t handle the power cable with wet hands High voltages present could cause lethal electric shock Warning Should any foreign substances enter the device...

Страница 5: ...elds inside the magnetic room have the potential to dislodge items at high velocities and can result in serious injury or death Caution For questions regarding installation procedures or technical sup...

Страница 6: ...se consult your Troyka Med Sales or Service office Always use the power supply cord supplied in the original shipping carton If the enclosed power cord could not be used due to a different standard in...

Страница 7: ...d to view patient in MRI scanner or overview MRI room The T 290 MRI Box Camera System is designed to be MRI conditional and is manufactured and tested to the highest standards The camera system is des...

Страница 8: ...7 2 3 5 85 Weight 520 g 3 4 Installation 3 4 1 Installation Diagram of MRI Video Camera in Magnet Room A representative drawing is showing the layout plan of the MRI video camera is given in Figure 2...

Страница 9: ...ctions before cleaning 4 1 1 Monitor Surface Dampen do not saturate a clean lint free cloth with environmentally friendly glass cleaner The cleaner contains spirit as an active substance up to 98 and...

Страница 10: ...Troyka Med Inc IOSB Mah 2284 Cad No 48 Yenimahalle Ankara TURKEY Tel 90 3122650096 info troykamed com www troykamed com T 290 MRI Conditional Box Camera Op Man Pub 022018 Pub No 0 Rev 0...

Отзывы: