LASER ENGRAVING&CUTTING CONTROLLER AWC608
、
24
【
Pulse Unit
】
:
When sending a pulse to the motor, the absolute distance moved by the
corresponding axis (unit: um). If the pulse unit setting is not correct, the processed image size will
be different from the actual size.
【
Pulse Edge
】
:
Trigger edge when motor rotated by motor driver
。
If the pulse edge setting is not
correct, may lead to cutting dislocation
【
Datum
】
:
Axes moving direction when reset
。
When the axial resetting movement direction is not
consistent with the shaft limit switch, need modify the parameter.
【
Key Direction
】
:LCD Panel key movement direction. When the direction is different from
movement, need modify the parameter
【
Range
】:
Machine workbench range, means the max movement distance of corresponding axes.
【
Start Speed
】:
Start speed of axes from stationary state. The greater value, the faster speed, then
causing bigger Stop dithering, need make reasonable adjustment according to the characteristics
of mechanical. The typical setting should be within in 5 ~ 20 mm/s.
【
Max Acc.
】
: Acceleration when axis making accelerated or decelerated movement. Too big setting
may leading to motor’s lost steps or dither; too small setting may cause slow
acceleration and then slow processing speed for whole image. For axis with big
inertia, such as Y axes corresponding with beams, typical setting to be within in
800
~
3000mm/s2 ; For axis with small inertia, such as X axes corresponding with
carts, typical setting to be within in 10000
~
20000mm/s2;
【
Max Speed
】
: The motor drive ability and inertia of moving axis decide the max speed that motion
axes can reach. During engraving process, engraving speed can not surpass the
max speed value corresponding with the engraving axis; During cutting process,
the resultant speed can not surpass the min speed of X and Y axis. If speed setting
is too large, controller will limit the speed below max speed automatically for
protection.
3.3.2.2 IO Function Switch (Refer to View 3-3-2)
【
Water Protect
】
:The water protect ports of AWC608 control panel are Laser1.Protect and
Laser2.Protect
。
When
【
Water Protect
】
is selected, system will apply real-time monitoring
water protection signal of the 2 ports, either of the port signal comes to be high level,
processing job will be suspended, and laser will be closed. Meanwhile “Water protect” will
be shown on LCD Panel.
【
Open Protect
】
:The open protect port of AWC608 control panel is IN1.When [Open protect] is
selected, system will apply real-time monitoring protection signal of the port, if the port
signal comes to be low level, processing job will be suspended; when the port signal
comes to be high level, suspended job will continue.
【
Foot Switch
】
: The foot switch port of AWC608 control panel is IN2.When [Foot Switch] is selected,
system will apply real-time monitoring protection signal of the port, if the port signal
changes from high level to low level, processing job will be suspended or suspended job
will continue.
3.3.2.3 Laser Parameters (Refer to View 3-3-2)
[Laser Mode]: Choose the parameters according to the external laser. The current lasers are mainly
of 3 kinds: domestic glass tube and RF laser (don't need burning pulse) and radio