![Trocen AWC608C Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/trocen/awc608c/awc608c_manual_1170755026.webp)
LASER ENGRAVING&CUTTING CONTROLLER AWC608
、
25
frequency laser (need burning pulse).
【
TTL Level
】
:Choose the parameters according to external laser power supply switch signals,
AWC608 laser switch signals corresponds with Laser1.TTL and Laser2.TTL.If [Low level
effective] is selected, when laser on, the system will output the two signals for low level,
when laser off, the system will output the two signals for high level; If [High level effective]
is selected, when laser on, the system will output the two signals for high level, when
laser off, the system will output the two signals for low level.
【
PWM Frequency
】
: Pulse frequency of control signal used by external laser. General setting will
be within 20000~80000.If setting is too small, it will lead to unbalanced power with
“Heavy Point” appeared during processing.
【
Max Power
】
: Limit power value that can be set for laser, namely during operation, process in
power set by user can not be above this value.
3.3.2.4 Function config (Refer to View 3-3-2)
【
XY axis home On Power
】
: Selected, when machine started, X axis and Y axis will run reset
movement simultaneously (Shall select the option normally)
【
Z axis home On Power
】
: Selected, when machine started, Z axis will run reset movement
(Shall not select the option normally)
【
U axis home On Power
】
: Selected, when machine started, U axis will run reset movement.
(Shall not select the option normally)
【
U axis for feeding
】
: It’s selected to start U axis feeding function. If it’s not selected, U axis feeding
function will not work. (Shall select the option normally)
【
Hardware limit
】
: Selected, System will apply real-time monitoring on limit signal according to the
direction of the movement. When detected a limit signal as low level, ongoing
work will suspend, and “Reach limit!” will be displayed on the LED.
【
Return origin after work
】
: Selected, system will return to origin after job complete; Not selected,
system will stay the same after job complete.
3.3.2.5 Manufacturer parameter import and export (Refer to View 3-3-2)
Filename extensions for parameter files is cf5
Manufacturer parameter import: allows import manufacturer’s complete setting parameter files.
Click [Import] and then import manufacturer parameter.
Manufacturer parameter export: allows copy the current parameter settings. Click [Export] and then
export current parameter. Moreover the exported parameter can be used to modify the current main
board parameter through AWC608 main board U disk port.
3.3.2.6 Manufacture Parameters Read and Save (Refer to View 3-3-2)
Filename extensions for parameter files is cf5
Manufacturer Parameter reading, namely, read and input the saved control panel parameter into the
software interface. Click [Read]
Manufacturer Parameter saving, namely, save the software interface settings into control panel