14
CONNECTING THE PCB CABLE
9
check list
SECTION
CONNECTING THE PCB CABLE
& REFITTING THE COVER
IMPORTANT:
After connecting the PCB cable,
please check the following before refitting the
cover:
1. All plumbing connections are watertight.
2. Terminal block screws are fully tightened.
3. Make sure the pipe and cable entering
the unit do not prevent the cover locating
correctly onto the backplate.
4. Check that the top rubber seal is in place
on the inside of the cover.
• See
(fig.13 & 14 on page 12)
for the
correct positions of the temperature spindle
and temperature knob.
•
Attached to the display PCB, inside
the cover, is a 10-way ribbon cable.
The ribbon cable connector must be
plugged into the socket located at the
right of the power PCB situated inside
the unit
(fig.17)
.
•
The cable connector can only be fitted
into the socket in one way. The ribbon
cable has a coloured edge which is
lowermost when correctly fitted to the
socket.
• Guide the cover into position so that the knob
spindle locates correctly (minor adjustment
may be necessary to align the knob and
spindle). Should any difficulty arise, re check
the points above.
• While applying slight pressure to the cover,
secure in position with the retaining screws.
• Turn the electric supply back on at the
isolating switch. The ‘
Power
’ indicator will
light.
• Water will
NOT
flow until one of the buttons
is pressed.
• It is recommended that the water and electric
supplies to the shower are turned off while
the riser rail kit is being installed.
• The flexible hose can be left attached to the
shower outlet. Make sure the supplied sealing
washer is fitted.
Fig.17
PCB
cable
(cover)
Coloured
edge
PCB (In shower)
WARNING
COVER RETAINING SCREWS
ONLY
the
SUPPLIED SCREWS
should be
used. The use of none supplied screws
WILL
invalidate product specifications & warranty.