Products manufactured by Triton are safe and without risk provided they are installed, used and 

maintained in good working order in accordance with our instructions and recommendations.

WARNING:

 

DO NOT

 operate shower if frozen, or suspected of being frozen. It must thaw out 

before using.

DO NOT

 operate the unit if the showerhead or spray hose becomes damaged.

DO NOT

 restrict flow out of shower by placing showerhead in direct contact with your body.

DO NOT

 operate the shower if water ceases to flow during use or if water has entered inside 

the unit because of an incorrectly fitted cover.

WARNING:

 If restarting the shower immediately after stopping, be aware that a slug of 

hot water will be expelled for the first few seconds.

PLEASE READ THIS IMPORTANT SAFETY INFORMATION

GENERAL

1.1 

Isolate the electrical and water supplies before 

removing the cover.

1.2 

Read all of these instructions and retain them 

for later use.

1.3 

DO NOT

 take risks with plumbing or electrical 

equipment.

1.4 

Isolate electrical and water supplies before 

proceeding with the installation.

1.5 

The unit must be mounted onto the finished 

wall surface (on top of the tiles). 

DO NOT

 tile 

up to or seal around 

ANY PART

 of the unit 

using silicone sealer after fixing to the wall. 

Special care must be taken 

NOT TO BLOCK 

OR SEAL ANY PRD VENTS ON THE UNIT

.

1.6 

Contact Customer Service 

(see back page)

, if 

any of the following occur:

a) 

If it is intended to operate the shower at 

pressures above the maximum or below the 

minimum stated.

b) 

If the unit shows a distinct change in performance.

c) 

If the shower is frozen.

1.7 

If it is intended to operate the shower in areas 

of hard water (above 200 ppm temporary 

hardness), a scale inhibitor may have to be 

fitted. For advice on the Scale Inhibitor, 

contact Customer Service.

1.8 

The showerhead must be cleaned regularly 

with descalent to remove scale and debris, 

otherwise restrictions to the flow on the outlet 

of the unit will result in higher temperatures 

and could also cause the (PRD) Pressure Relief 

Device in the unit to operate.

1.9 

This product is not suitable for mounting into 

steam rooms or steam cubicles.

PLUMBING

2.1 

The plumbing installation must comply with 

Water Regulations, Building Regulations or any 

particular regulations as specified by Local 

Water Company or Water Undertakers and 

should be in accordance with BS EN 806.

2.2 

The supply pipe must be flushed to clear debris 

before connecting to the shower unit.

2.3 

DO NOT

 solder pipes or fittings within 300mm 

of the shower unit, as heat can transfer along 

the pipework and damage components.

2.4 

DO NOT

 fit any form of outlet flow control as 

the outlet acts as a vent for the heater can.

2.5 

DO NOT

 use excessive force when making 

connections to the flexible hose or 

showerhead, finger tight is sufficient.

2.6 

All plumbing connections must be completed 

before making the electrical connections.

2.7 

This appliance 

MUST 

not be connected to the 

inlet supply by a hose-set.

ELECTRICAL

3.1 

The installation must comply with BS 7671 

‘Requirements for electrical installations’ (IEE 

wiring regulations), building regulations or any 

particular regulations as specified by the local 

Electrical Supply Company.

3.2 

This appliance 

MUST 

be earthed.

3.3 

In accordance with ‘The Plugs and Sockets etc. 

(Safety) Regulations 1994’, this appliance is 

intended to be permanently connected to the 

fixed wiring of the electrical mains system.

3.4 

Make sure all electrical connections are tight to 

prevent overheating.

3.5 

A 30mA residual current device (RCD) 

MUST 

be installed in all UK electric and pumped 

shower circuits. This may be part of the 

consumer unit or a separate unit.

3.6 

Switch off immediately at isolating switch if 

water ceases to flow during use.

3.7 

Other electrical equipment i.e. extractor fans, 

pumps must not be connected to the circuits 

within the unit.

3.8 

Switch off at isolating switch when not in use. 

This is a safety procedure recommended with 

all electrical appliances.

3.9 

As with all electrical appliances it is 

recommended to have the shower and 

installation checked at least every two years by 

a competent electrician to ensure there is no 

deterioration due to age and usage.

IMPORTANT - GENERAL GUIDANCE NOTES

WARNING

This appliance can be used by children aged from 8 years and above and persons with 

reduced physical, sensory or mental capabilities or lack of experience or knowledge if 

they have been given supervision or instruction concerning use of the appliance in a safe 

way and understand the hazards involved. Children may not play with the appliance. 

Cleaning and user maintenance shall not be made by children without supervision

.

Содержание Aspirante 8.5kW

Страница 1: ...on and keep it for future reference The shower installation MUST be carried out by a suitably qualified person in the sequence of this instruction book Installation and operating instructions Installe...

Страница 2: ...t is intended to operate the shower at pressures above the maximum or below the minimum stated b If the unit shows a distinct change in performance c If the shower is frozen 1 7 If it is intended to o...

Страница 3: ...pipes or fittings within 300mm of the shower unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the hea...

Страница 4: ...ar to or below the minimum level The drop in pressure may be due to water being drawn off at other points in the house whilst the shower is in use If pressure drops appreciably below the minimum the h...

Страница 5: ...7 Plumbing installation 8 Electrical installation 9 Fit to the wall connect shower supplies 9 11 Fitting the cover 12 COMMISSIONING PROCEDURE 13 14 Connecting the PCB cable 14 USER OPERATING INSTRUCTI...

Страница 6: ...00 kPa 10 bar Maximum inlet temperature 28 C Minimum inlet temperature 2 C Inlet connection 15mm diameter Outlet connection BSP male thread MATERIALS ABS Backplate cover controls showerhead Acetal Spr...

Страница 7: ...m 94mm 300mm ENTRY POINTS DIMENSIONS WATER Left Top Bottom Side Back Right Bottom Side Back CABLE Left Top Bottom Side back Right None Back Back Others Others PLEASE NOTE Deviation from the approved e...

Страница 8: ...in any doubt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a r...

Страница 9: ...while standing in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlet...

Страница 10: ...ing to achieve your preferred shower temperature Fig 5 shows a typical system layout Refer to fig 6 for the correct siting of the shower Position the unit where it will NOT be in direct contact with w...

Страница 11: ...er hose or a blocked showerhead This may cause the PRD to operate When commissioning the showerhead must be removed from the flexible hose Failure to follow this procedure may cause the PRD to operate...

Страница 12: ...e wall This area MUST be left clear when plastering and tiling around the pipework in order to make the nut accessible for future adjustments NOTE An additional stopvalve complying with Water Regulati...

Страница 13: ...been chosen the trim can be fitted complete Should either top cable or top pipe entry have been chosen individually the trim has been designed to be separated and the appropriate trim section can be...

Страница 14: ...he wall and tighten the retaining screws which hold it to the wall Turn on the mains water supply and check for leaks in the pipework connection to the shower NOTE At this stage no water can flow thro...

Страница 15: ...earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The use of connections within the unit or other points in the shower circuit to supply power...

Страница 16: ...tes correctly minor adjustment may be necessary to align the control and spindle Should any difficulty arise recheck the points above While applying slight pressure to the front cover secure in positi...

Страница 17: ...could make the PRD operate Turn on the water supply to the shower at the isolating stop valve Switch on the electricity supply to the shower at the isolating switch Wait until water starts to flow fr...

Страница 18: ...fitted into the socket in one way The ribbon cable has a coloured edge which is lowermost when correctly fitted to the socket Guide the cover into position so that the knob spindle locates correctly...

Страница 19: ...ll start on the High setting To stop the shower The shower can be stopped by pressing the start stop button When pressed the phased shutdown will begin and water will cease to flow after a few seconds...

Страница 20: ...ges in ambient water temperature NOTE The preferred knob position on ECONOMY will give a different temperature to the same position on HIGH To decrease the shower temperature Turn the temperature cont...

Страница 21: ...ater pressure the unit automatically restores the power to the elements and returns to the original setting selected Phased shutdown In use every time the Start Stop button is pressed power is switche...

Страница 22: ...plate Unscrew the filter cap from the bottom of the inlet pipe Inspect the O ring for damage when the filter cap is removed When cleaning the filter DO NOT use a sharp object as it will cause damage I...

Страница 23: ...2 2 1 Check if stop valves are fully open Check if a blockage in the inlet filter 2 3 Increase in ambient water temperature 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power...

Страница 24: ...5 1 Thermal safety cut out device has operated Have the unit checked by a suitably qualified engineer or contact Customer Service 4 Pressure relief device has operated water ejected from PRD tube 4 1...

Страница 25: ...et S27411001 8 Water Outlet bottom TCO S27411002 9 Main Trimplate White 7054130 Black 7054144 10 Power PCB 7073732 11 Cover assembly including cover PCB Gloss Black S27410606 Gloss White S27410607 Gun...

Страница 26: ...der the following schemes Repic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled...

Страница 27: ...OF THE ELEMENTS USED HEATER ELEMENTS USED 2 OF THE ELEMENTS USED 0 1 2 H O T HOT COLD To START the shower button A B C or D can be pressed and water will flow from the shower Press A Start Stop and Hi...