Installation

 - PLUMBING INSTALLATION

PLUMBING INSTALLATION

Plumbing to be carried out before wiring

• 

DO NOT

 use jointing compounds on any 

pipe fittings for the installation.

• 

DO NOT

 solder fittings near the shower unit 

as heat can transfer along the pipework and 
damage components.

•  Compression fittings 

MUST

 be used to 

connect to the inlet of the shower 

(fig.7)

.  

(Push-on fittings must 

NOT

 be used as full 

engagement cannot be guaranteed).

•  If installing a feed pipe from the back or 

bottom, the centre of the inlet valve to the 
wall surface is 21mm 

(fig.7a)

.

• 

IMPORTANT LEFT OR RIGHT REAR 
ENTRY FITTING INFORMATION (fig.7b). 

Depending on the manufacturer of the *90° 
compression fitting, the water inlet pipe may 
need to be trimmed 

(by a 

maximum

 of 7mm)

 

to allow the main trim to be fitted correctly 
once the compression fitting is in place. It 
is advised to check positioning of the 90° 
compression fitting and main trim fit before 
any fittings are tightened.

NOTE:

 

If entry is from the back, the nut of the 

compression fitting will be partially behind the 
surface of the wall. This area MUST be left clear 
when plastering and tiling around the pipework 
in order to make the nut accessible for future 
adjustments.

NOTE: 

An additional stopvalve (complying with 

Water Regulations) must be fitted in the mains 
water supply to the shower as an independent 
means of isolating the water supply should 
maintenance or servicing be necessary.

IMPORTANT: 

Before completing the connection 

of the water supply to the inlet of the shower, flush 
out the pipework to remove all swarf and system 
debris. This can be achieved by connecting a hose 
to the pipework and turning on the mains water 
supply long enough to clear the debris to waste.

IMPORTANT INFORMATION

The outlet of the shower acts as a vent and 

must not be connected to anything other 

than the hose and showerhead supplied.

5

check list

 SECTION

21mm

Fig.7a

*Due to variations in manufacturers specifications, it is beyond  

the scope of this book to recommend a specific elbow brand.

7mm

(maximum)

The inlet elbow should be trimmed square and any 

rough edges or burrs removed.

Fig.7b

IMPORTANT!

The water inlet MUST ONLY be used 

in the ‘Left’ or ‘Right’ entry position. 

Under NO CIRCUMSTANCES  should the 

water inlet fitting be used at 90° to 

the backplate to emulate a ‘Rear Entry’ 

installation.

Содержание Aspirante 8.5kW

Страница 1: ...on and keep it for future reference The shower installation MUST be carried out by a suitably qualified person in the sequence of this instruction book Installation and operating instructions Installe...

Страница 2: ...t is intended to operate the shower at pressures above the maximum or below the minimum stated b If the unit shows a distinct change in performance c If the shower is frozen 1 7 If it is intended to o...

Страница 3: ...pipes or fittings within 300mm of the shower unit as heat can transfer along the pipework and damage components 2 4 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the hea...

Страница 4: ...ar to or below the minimum level The drop in pressure may be due to water being drawn off at other points in the house whilst the shower is in use If pressure drops appreciably below the minimum the h...

Страница 5: ...7 Plumbing installation 8 Electrical installation 9 Fit to the wall connect shower supplies 9 11 Fitting the cover 12 COMMISSIONING PROCEDURE 13 14 Connecting the PCB cable 14 USER OPERATING INSTRUCTI...

Страница 6: ...00 kPa 10 bar Maximum inlet temperature 28 C Minimum inlet temperature 2 C Inlet connection 15mm diameter Outlet connection BSP male thread MATERIALS ABS Backplate cover controls showerhead Acetal Spr...

Страница 7: ...m 94mm 300mm ENTRY POINTS DIMENSIONS WATER Left Top Bottom Side Back Right Bottom Side Back CABLE Left Top Bottom Side back Right None Back Back Others Others PLEASE NOTE Deviation from the approved e...

Страница 8: ...in any doubt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a r...

Страница 9: ...while standing in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlet...

Страница 10: ...ing to achieve your preferred shower temperature Fig 5 shows a typical system layout Refer to fig 6 for the correct siting of the shower Position the unit where it will NOT be in direct contact with w...

Страница 11: ...er hose or a blocked showerhead This may cause the PRD to operate When commissioning the showerhead must be removed from the flexible hose Failure to follow this procedure may cause the PRD to operate...

Страница 12: ...e wall This area MUST be left clear when plastering and tiling around the pipework in order to make the nut accessible for future adjustments NOTE An additional stopvalve complying with Water Regulati...

Страница 13: ...been chosen the trim can be fitted complete Should either top cable or top pipe entry have been chosen individually the trim has been designed to be separated and the appropriate trim section can be...

Страница 14: ...he wall and tighten the retaining screws which hold it to the wall Turn on the mains water supply and check for leaks in the pipework connection to the shower NOTE At this stage no water can flow thro...

Страница 15: ...earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The use of connections within the unit or other points in the shower circuit to supply power...

Страница 16: ...tes correctly minor adjustment may be necessary to align the control and spindle Should any difficulty arise recheck the points above While applying slight pressure to the front cover secure in positi...

Страница 17: ...could make the PRD operate Turn on the water supply to the shower at the isolating stop valve Switch on the electricity supply to the shower at the isolating switch Wait until water starts to flow fr...

Страница 18: ...fitted into the socket in one way The ribbon cable has a coloured edge which is lowermost when correctly fitted to the socket Guide the cover into position so that the knob spindle locates correctly...

Страница 19: ...ll start on the High setting To stop the shower The shower can be stopped by pressing the start stop button When pressed the phased shutdown will begin and water will cease to flow after a few seconds...

Страница 20: ...ges in ambient water temperature NOTE The preferred knob position on ECONOMY will give a different temperature to the same position on HIGH To decrease the shower temperature Turn the temperature cont...

Страница 21: ...ater pressure the unit automatically restores the power to the elements and returns to the original setting selected Phased shutdown In use every time the Start Stop button is pressed power is switche...

Страница 22: ...plate Unscrew the filter cap from the bottom of the inlet pipe Inspect the O ring for damage when the filter cap is removed When cleaning the filter DO NOT use a sharp object as it will cause damage I...

Страница 23: ...2 2 1 Check if stop valves are fully open Check if a blockage in the inlet filter 2 3 Increase in ambient water temperature 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power...

Страница 24: ...5 1 Thermal safety cut out device has operated Have the unit checked by a suitably qualified engineer or contact Customer Service 4 Pressure relief device has operated water ejected from PRD tube 4 1...

Страница 25: ...et S27411001 8 Water Outlet bottom TCO S27411002 9 Main Trimplate White 7054130 Black 7054144 10 Power PCB 7073732 11 Cover assembly including cover PCB Gloss Black S27410606 Gloss White S27410607 Gun...

Страница 26: ...der the following schemes Repic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9659 All our electric products are labelled...

Страница 27: ...OF THE ELEMENTS USED HEATER ELEMENTS USED 2 OF THE ELEMENTS USED 0 1 2 H O T HOT COLD To START the shower button A B C or D can be pressed and water will flow from the shower Press A Start Stop and Hi...

Страница 28: ...including post code the model number and power rating of the product together with the date of purchase and where applicable details of the particular fault 2 If required the Customer Service Advisor...

Отзывы: